Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 108
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-12-15 11:11 to 2023-12-15 12:15 UTC
Where: 55° 14.9' S 152° 49.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 10.3 | 335.27 | 33.860 | 26.64 | 2.72 | 1.85 | 0.21 | 0.23 | 13.18 |
36 | 10.4 | < 0.02 | < 0.02 | < 0.02 | 2.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 2.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 34.9 | 335.58 | 33.860 | 26.60 | 2.73 | 1.85 | 0.21 | 0.22 | 13.11 |
31 | 34.9 | < 0.02 | < 0.02 | < 0.02 | 2.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 35.1 | < 0.02 | < 0.02 | < 0.02 | 2.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 75.2 | 335.45 | 33.860 | 26.62 | 2.71 | 1.86 | 0.23 | 0.22 | 13.25 |
28 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 2.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 75.3 | < 0.02 | < 0.02 | < 0.02 | 2.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 120.6 | < 0.02 | < 0.02 | < 0.02 | 2.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 120.7 | 338.66 | 33.879 | 27.87 | 2.06 | 1.99 | 0.46 | 0.22 | 19.49 |
27 | 120.7 | < 0.02 | < 0.02 | < 0.02 | 2.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 220 | < 0.02 | < 0.02 | < 0.02 | 1.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 220.1 | 273.77 | 34.103 | 31.92 | 2.00 | 2.25 | 0.08 | 0.06 | 35.91 |
24 | 220.2 | < 0.02 | < 0.02 | < 0.02 | 2.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 340.5 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 340.8 | 218.70 | 34.327 | 34.76 | 1.95 | 2.45 | < 0.02 | 0.02 | 58.25 |
21 | 341 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 439.7 | < 0.02 | < 0.02 | < 0.02 | 2.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 439.8 | 189.72 | 34.442 | 35.36 | 2.24 | 2.50 | < 0.02 | < 0.02 | 66.86 |
18 | 439.9 | < 0.02 | < 0.02 | < 0.02 | 2.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 549.7 | 175.07 | 34.544 | 35.21 | 2.36 | 2.48 | < 0.02 | < 0.02 | 74.06 |
13 | 549.8 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 549.9 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 659.9 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 659.9 | 173.69 | 34.593 | 34.68 | 2.35 | 2.44 | < 0.02 | < 0.02 | 76.93 |
12 | 660 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 800.3 | < 0.02 | < 0.02 | < 0.02 | 2.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 800.5 | 176.46 | 34.646 | 33.88 | 2.27 | 2.40 | < 0.02 | < 0.02 | 80.12 |
9 | 800.6 | < 0.02 | < 0.02 | < 0.02 | 2.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 999.9 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1000.1 | 184.36 | 34.701 | 32.40 | 2.22 | 2.30 | < 0.02 | < 0.02 | 81.89 |
2 | 1200.1 | 189.59 | 34.722 | 31.83 | 2.13 | 2.25 | < 0.02 | < 0.02 | 84.23 |
1 | 1200.1 | < 0.02 | < 0.02 | < 0.02 | 2.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1200.2 | < 0.02 | < 0.02 | < 0.02 | 2.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |