Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 63
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-12-03 19:15 to 2023-12-03 22:17 UTC
Where: 56° 26.4' S 152° 22.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 2.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 10.2 | 344.51 | 33.894 | 27.92 | 2.26 | 1.87 | 0.21 | 0.23 | 19.72 |
34 | 35.3 | < 0.02 | < 0.02 | < 0.02 | 2.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 35.3 | 343.98 | 33.895 | 27.93 | 2.26 | 1.91 | 0.20 | 0.23 | 19.72 |
32 | 65.2 | < 0.02 | < 0.02 | < 0.02 | 2.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 65.2 | 343.53 | 33.895 | 27.92 | 2.25 | 1.90 | 0.22 | 0.24 | 19.74 |
29 | 150.6 | 319.86 | 34.019 | 31.07 | 1.09 | 2.16 | 0.30 | 0.18 | 35.77 |
30 | 150.7 | < 0.02 | < 0.02 | < 0.02 | 1.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 260.3 | 195.53 | 34.388 | 35.85 | 2.38 | 2.47 | 0.04 | 0.03 | 61.90 |
27 | 350.4 | 180.25 | 34.483 | 36.35 | 2.31 | 2.50 | < 0.02 | 0.02 | 70.93 |
26 | 450.7 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 451.1 | 173.46 | 34.566 | 35.65 | 2.37 | 2.46 | < 0.02 | 0.02 | 75.65 |
24 | 600.6 | 177.13 | 34.641 | 34.36 | 2.34 | 2.37 | < 0.02 | 0.02 | 78.73 |
22 | 700.4 | 180.97 | 34.668 | 33.73 | 2.30 | 2.33 | < 0.02 | 0.02 | 79.95 |
23 | 700.4 | < 0.02 | < 0.02 | < 0.02 | 2.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 820.5 | 186.01 | 34.700 | 32.80 | 2.25 | 2.27 | < 0.02 | 0.02 | 81.28 |
19 | 940.3 | 189.09 | 34.710 | 32.42 | 2.19 | 2.25 | < 0.02 | 0.02 | 82.60 |
20 | 940.3 | < 0.02 | < 0.02 | < 0.02 | 2.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 1050.5 | 191.64 | 34.726 | 32.16 | 2.10 | 2.23 | < 0.02 | 0.02 | 84.67 |
18 | 1050.5 | < 0.02 | < 0.02 | < 0.02 | 2.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1200.3 | 195.08 | 34.734 | 31.88 | 1.97 | 2.21 | < 0.02 | 0.02 | 87.83 |
15 | 1450.2 | < 0.02 | < 0.02 | < 0.02 | 1.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1450.3 | 200.22 | 34.742 | 31.68 | 1.77 | 2.20 | < 0.02 | 0.02 | 93.26 |
12 | 1700.2 | 203.61 | 34.739 | 31.78 | 1.56 | 2.21 | < 0.02 | < 0.02 | 99.59 |
13 | 1700.3 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 2000.3 | 207.27 | 34.729 | 32.18 | 1.27 | 2.24 | < 0.02 | < 0.02 | 108.56 |
11 | 2000.4 | < 0.02 | < 0.02 | < 0.02 | 1.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2300.8 | 209.55 | 34.720 | 32.58 | 1.07 | 2.27 | < 0.02 | 0.02 | 116.13 |
8 | 2600.4 | 212.72 | 34.711 | 32.80 | 0.92 | 2.29 | < 0.02 | 0.02 | 120.58 |
7 | 2800.6 | < 0.02 | < 0.02 | < 0.02 | 0.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2800.8 | 214.24 | 34.707 | 33.00 | 0.83 | 2.30 | < 0.02 | 0.02 | 123.71 |
5 | 3100.6 | 216.70 | 34.698 | 33.12 | 0.72 | 2.30 | < 0.02 | 0.02 | 126.98 |
4 | 3467.6 | < 0.02 | < 0.02 | < 0.02 | 0.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3467.7 | 219.24 | 34.692 | 33.21 | 0.61 | 2.31 | < 0.02 | < 0.02 | 129.48 |
1 | 3530.9 | 219.60 | 34.690 | 33.29 | 0.60 | 2.32 | < 0.02 | < 0.02 | 129.62 |
2 | 3531 | < 0.02 | < 0.02 | < 0.02 | 0.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |