Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 58
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-12-02 04:06 to 2023-12-02 05:10 UTC
Where: 56° 07.7' S 152° 10.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
34 | 9.1 | < 0.02 | < 0.02 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 9.6 | 341.97 | 33.886 | 27.56 | 2.45 | 1.89 | 0.28 | 0.23 | 19.46 |
36 | 9.6 | < 0.02 | < 0.02 | < 0.02 | 2.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 31.6 | 342.55 | 33.885 | 27.58 | 2.44 | 1.89 | 0.26 | 0.23 | 19.54 |
33 | 31.7 | < 0.02 | < 0.02 | < 0.02 | 2.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 32 | < 0.02 | < 0.02 | < 0.02 | 2.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 71.4 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 71.6 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 71.6 | 342.55 | 33.905 | 28.25 | 2.00 | 1.98 | 0.33 | 0.23 | 22.76 |
26 | 121.7 | 327.45 | 34.016 | 30.66 | 0.97 | 2.17 | 0.41 | 0.19 | 35.87 |
27 | 121.8 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 121.8 | < 0.02 | < 0.02 | < 0.02 | 0.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 201.4 | < 0.02 | < 0.02 | < 0.02 | 1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 201.5 | 234.11 | 34.279 | 34.70 | 1.74 | 2.42 | 0.03 | 0.07 | 54.95 |
24 | 201.5 | < 0.02 | < 0.02 | < 0.02 | 1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 300.6 | 179.94 | 34.478 | 35.90 | 2.35 | 2.51 | 0.03 | < 0.02 | 69.95 |
19 | 300.6 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 300.7 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 451.3 | < 0.02 | < 0.02 | < 0.02 | 2.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 451.5 | 174.18 | 34.581 | 35.03 | 2.41 | 2.46 | 0.03 | < 0.02 | 75.09 |
18 | 451.6 | < 0.02 | < 0.02 | < 0.02 | 2.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 600.5 | < 0.02 | < 0.02 | < 0.02 | 2.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 600.5 | 175.29 | 34.643 | 34.29 | 2.28 | 2.40 | 0.02 | < 0.02 | 79.56 |
15 | 600.7 | < 0.02 | < 0.02 | < 0.02 | 2.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 749.3 | 180.83 | 34.683 | 33.31 | 2.19 | 2.34 | 0.03 | < 0.02 | 81.88 |
10 | 749.3 | < 0.02 | < 0.02 | < 0.02 | 2.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 749.4 | < 0.02 | < 0.02 | < 0.02 | 2.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 896.7 | < 0.02 | < 0.02 | < 0.02 | 2.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 896.8 | < 0.02 | < 0.02 | < 0.02 | 2.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 896.8 | 186.19 | 34.712 | 32.54 | 2.12 | 2.29 | 0.02 | < 0.02 | 83.53 |
5 | 1047.7 | 191.60 | 34.728 | 32.14 | 2.01 | 2.26 | 0.03 | < 0.02 | 86.00 |
6 | 1047.7 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1047.9 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1201 | 196.02 | 34.740 | 31.74 | 1.86 | 2.24 | 0.03 | < 0.02 | 89.97 |
3 | 1201 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1201.2 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |