Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 41
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-11-30 01:51 to 2023-11-30 04:48 UTC
Where: 55° 03.8' S 151° 29.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 10 | < 0.02 | < 0.02 | < 0.02 | 4.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 10.1 | 321.74 | 33.953 | 23.53 | 4.96 | 1.64 | 0.17 | 0.21 | 7.65 |
34 | 36 | < 0.02 | < 0.02 | < 0.02 | 4.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 36 | 322.18 | 33.946 | 23.56 | 4.95 | 1.65 | 0.17 | 0.20 | 7.64 |
31 | 80.4 | 319.28 | 33.974 | 23.02 | 5.05 | 1.64 | 0.19 | 0.20 | 7.45 |
32 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 5.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 121.5 | 322.59 | 33.935 | 23.93 | 4.68 | 1.69 | 0.21 | 0.21 | 7.89 |
30 | 121.6 | < 0.02 | < 0.02 | < 0.02 | 4.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 161.2 | 300.39 | 34.117 | 22.63 | 5.56 | 1.60 | < 0.02 | 0.07 | 6.88 |
26 | 211.6 | 297.35 | 34.099 | 23.45 | 5.26 | 1.66 | < 0.02 | 0.03 | 7.75 |
27 | 212.1 | < 0.02 | < 0.02 | < 0.02 | 5.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 411.3 | 235.50 | 34.250 | 29.15 | 4.78 | 2.03 | < 0.02 | 0.02 | 22.15 |
25 | 412 | < 0.02 | < 0.02 | < 0.02 | 4.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 541.7 | 227.64 | 34.252 | 31.54 | 3.84 | 2.20 | < 0.02 | < 0.02 | 31.84 |
23 | 542 | < 0.02 | < 0.02 | < 0.02 | 3.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 700 | 209.95 | 34.308 | 33.79 | 3.11 | 2.36 | < 0.02 | < 0.02 | 45.80 |
19 | 852.7 | 186.46 | 34.431 | 34.68 | 3.02 | 2.44 | < 0.02 | < 0.02 | 59.39 |
20 | 853.2 | < 0.02 | < 0.02 | < 0.02 | 3.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 1000.8 | 178.06 | 34.503 | 34.82 | 2.82 | 2.46 | < 0.02 | < 0.02 | 67.21 |
17 | 1199.7 | < 0.02 | < 0.02 | < 0.02 | 2.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1199.8 | 175.79 | 34.583 | 34.31 | 2.64 | 2.43 | < 0.02 | < 0.02 | 73.55 |
15 | 1449.3 | 179.45 | 34.657 | 33.28 | 2.47 | 2.35 | < 0.02 | < 0.02 | 77.77 |
14 | 1698.9 | < 0.02 | < 0.02 | < 0.02 | 2.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1699.3 | 186.86 | 34.710 | 32.15 | 2.28 | 2.27 | < 0.02 | < 0.02 | 82.56 |
12 | 1949.2 | 192.22 | 34.732 | 31.66 | 2.12 | 2.24 | < 0.02 | < 0.02 | 87.12 |
10 | 2198.3 | 197.71 | 34.742 | 31.41 | 1.87 | 2.23 | < 0.02 | < 0.02 | 93.44 |
11 | 2198.8 | < 0.02 | < 0.02 | < 0.02 | 1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2479.7 | 201.56 | 34.738 | 31.63 | 1.61 | 2.24 | < 0.02 | < 0.02 | 101.59 |
8 | 2749.6 | 206.02 | 34.731 | 31.81 | 1.38 | 2.26 | < 0.02 | < 0.02 | 107.46 |
7 | 3051.4 | 208.61 | 34.720 | 32.29 | 1.15 | 2.29 | < 0.02 | < 0.02 | 116.39 |
5 | 3400.2 | 211.20 | 34.712 | 32.55 | 1.00 | 2.31 | < 0.02 | < 0.02 | 121.45 |
6 | 3400.3 | < 0.02 | < 0.02 | < 0.02 | 1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3750.8 | < 0.02 | < 0.02 | < 0.02 | 0.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3751 | 216.07 | 34.701 | 32.71 | 0.80 | 2.33 | < 0.02 | < 0.02 | 126.51 |
2 | 3800.1 | < 0.02 | < 0.02 | < 0.02 | 0.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3800.7 | 216.34 | 34.700 | 32.72 | 0.78 | 2.33 | < 0.02 | < 0.02 | 126.89 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |