Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CDOM CTD 25 - SN 7138,CTD 23 - SN 1312,Conductivity CTD 23-SN 4662,Fluorometer - CTD 23 - WET Labs ECO FLNTU,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3159,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 23 - Wetlabs ECO,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1421DR
When: 2023-02-22 23:08 to 2023-02-23 00:16 UTC
Where: 35° 18.9' S 118° 35.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
33 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 21.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 21.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 21.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 7.1 | 227.50 | 35.672 | 0.04 | 21.39 | 0.05 | < 0.02 | < 0.02 | 1.96 |
35 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 21.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 20.6 | < 0.02 | < 0.02 | < 0.02 | 21.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 20.9 | 229.96 | < 0.02 | 0.05 | 21.25 | 0.05 | < 0.02 | < 0.02 | 1.93 |
29 | 50.6 | 236.35 | < 0.02 | 0.05 | 19.78 | 0.05 | < 0.02 | 0.02 | 1.46 |
28 | 75.4 | < 0.02 | < 0.02 | < 0.02 | 18.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 18.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 75.5 | 232.91 | < 0.02 | 0.14 | 18.84 | 0.10 | < 0.02 | 0.06 | 1.92 |
25 | 150.5 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 150.5 | 248.14 | < 0.02 | 2.40 | 14.10 | 0.33 | < 0.02 | 0.13 | 1.01 |
23 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 13.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 200.6 | 246.80 | 35.233 | 3.73 | 13.51 | 0.41 | < 0.02 | 0.02 | 1.01 |
21 | 299.9 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 299.9 | 236.66 | 35.061 | 8.90 | 12.06 | 0.70 | < 0.02 | 0.02 | 1.73 |
19 | 400.5 | < 0.02 | < 0.02 | < 0.02 | 10.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 400.5 | 239.70 | 34.827 | 14.75 | 10.22 | 1.04 | < 0.02 | 0.02 | 3.51 |
16 | 500.1 | < 0.02 | < 0.02 | < 0.02 | 9.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 500.3 | < 0.02 | < 0.02 | < 0.02 | 9.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 500.4 | < 0.02 | < 0.02 | < 0.02 | 9.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 500.6 | 242.29 | 34.708 | 17.00 | 9.41 | 1.18 | < 0.02 | < 0.02 | 4.71 |
13 | 600.6 | < 0.02 | < 0.02 | < 0.02 | 8.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 600.8 | 235.99 | 34.607 | 19.52 | 8.66 | 1.33 | < 0.02 | < 0.02 | 6.62 |
10 | 699.5 | 207.58 | 34.471 | 25.65 | 7.19 | 1.72 | < 0.02 | < 0.02 | 15.17 |
11 | 699.6 | < 0.02 | < 0.02 | < 0.02 | 7.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 800.5 | 200.17 | 34.400 | 29.32 | 5.78 | 1.98 | < 0.02 | < 0.02 | 25.14 |
9 | 800.6 | < 0.02 | < 0.02 | < 0.02 | 5.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 900.3 | < 0.02 | < 0.02 | < 0.02 | 4.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 900.4 | 196.46 | 34.384 | 31.51 | 4.81 | 2.15 | < 0.02 | < 0.02 | 35.45 |
3 | 1061.4 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1061.4 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1061.6 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1061.7 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1061.8 | 186.37 | 34.416 | 33.87 | 3.77 | 2.32 | < 0.02 | < 0.02 | 51.60 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Fluorometer - CTD 23 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3159 | Seabird | SBE43 | 3159 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 23 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |