Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 74
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-28 07:38 to 2023-10-28 09:32 UTC
Where: 33° 32.3' S 154° 19.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 21.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 21.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 21.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.6 | 221.74 | 35.486 | 0.18 | 21.92 | 0.14 | 0.04 | 0.07 | 0.40 |
| 33 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 21.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 25.4 | < 0.02 | < 0.02 | 0.19 | 21.93 | 0.14 | 0.04 | 0.08 | 0.38 |
| 31 | 25.8 | < 0.02 | < 0.02 | < 0.02 | 21.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 21.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 50.7 | 221.56 | 35.485 | 0.19 | 21.93 | 0.15 | 0.06 | 0.08 | 0.39 |
| 26 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 21.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 21.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 75.7 | 220.13 | 35.486 | 0.28 | 21.91 | 0.15 | 0.07 | 0.09 | 0.39 |
| 24 | 120.7 | < 0.02 | < 0.02 | < 0.02 | 21.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 120.8 | 221.79 | 35.537 | 1.06 | 21.27 | 0.19 | < 0.02 | 0.30 | 0.45 |
| 22 | 150.6 | < 0.02 | < 0.02 | < 0.02 | 21.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 150.7 | 216.16 | 35.542 | 1.03 | 21.18 | 0.19 | < 0.02 | 0.27 | 0.41 |
| 20 | 200.5 | < 0.02 | < 0.02 | 2.53 | 20.18 | 0.26 | < 0.02 | 0.03 | 0.82 |
| 19 | 220.8 | 213.97 | 35.627 | 1.91 | 19.88 | 0.22 | < 0.02 | 0.03 | 0.68 |
| 18 | 250.5 | < 0.02 | < 0.02 | 2.22 | 19.69 | 0.25 | < 0.02 | 0.02 | 0.78 |
| 17 | 280.8 | < 0.02 | < 0.02 | 2.80 | 19.16 | 0.29 | < 0.02 | 0.02 | 0.93 |
| 16 | 300.1 | 204.41 | 35.615 | 3.89 | 18.66 | 0.35 | < 0.02 | 0.02 | 1.21 |
| 15 | 350.5 | < 0.02 | < 0.02 | 3.74 | 18.16 | 0.33 | < 0.02 | 0.02 | 1.19 |
| 14 | 400.1 | < 0.02 | < 0.02 | 4.79 | 17.67 | 0.41 | < 0.02 | 0.02 | 1.50 |
| 13 | 450.8 | 207.72 | 35.504 | 6.18 | 16.65 | 0.50 | < 0.02 | < 0.02 | 1.90 |
| 12 | 500.4 | < 0.02 | < 0.02 | 7.73 | 15.35 | 0.60 | < 0.02 | < 0.02 | 2.46 |
| 11 | 550 | < 0.02 | < 0.02 | 11.99 | 13.97 | 0.87 | < 0.02 | 0.02 | 3.94 |
| 10 | 600.9 | 205.49 | 35.148 | 12.32 | 12.94 | 0.89 | < 0.02 | 0.02 | 4.07 |
| 9 | 701.4 | < 0.02 | < 0.02 | 16.92 | 10.71 | 1.18 | < 0.02 | < 0.02 | 6.02 |
| 8 | 800.3 | < 0.02 | < 0.02 | 21.53 | 9.00 | 1.48 | < 0.02 | < 0.02 | 9.82 |
| 7 | 900.9 | < 0.02 | < 0.02 | 24.25 | 7.77 | 1.66 | < 0.02 | < 0.02 | 13.88 |
| 6 | 1001.4 | 206.65 | 34.455 | 26.54 | 6.81 | 1.82 | < 0.02 | < 0.02 | 19.24 |
| 5 | 1200.5 | < 0.02 | < 0.02 | 32.25 | 5.41 | 2.22 | < 0.02 | 0.02 | 55.20 |
| 4 | 1400.7 | < 0.02 | < 0.02 | 33.21 | 4.33 | 2.30 | < 0.02 | 0.02 | 59.02 |
| 3 | 1601.3 | 162.39 | 34.535 | 35.00 | 3.56 | 2.44 | < 0.02 | < 0.02 | 78.20 |
| 2 | 1801.5 | < 0.02 | < 0.02 | 35.83 | 3.04 | 2.51 | < 0.02 | < 0.02 | 92.08 |
| 1 | 2001.2 | 159.62 | 34.629 | 35.61 | 2.61 | 2.48 | < 0.02 | < 0.02 | 97.10 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |