Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-09 20:34 to 2023-10-09 21:10 UTC
Where: 33° 16.9' S 152° 14.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 3 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 4 | 237.33 | 35.525 | 0.08 | 20.16 | 0.13 | 0.05 | 0.03 | 0.07 |
| 34 | 4 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 8.7 | 237.33 | 35.526 | 0.09 | 20.16 | 0.14 | 0.08 | 0.03 | 0.07 |
| 25 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 18.9 | < 0.02 | < 0.02 | < 0.02 | 20.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 19.2 | 240.63 | 35.525 | 0.14 | 20.14 | 0.15 | 0.10 | 0.04 | 0.10 |
| 21 | 43.2 | < 0.02 | < 0.02 | < 0.02 | 19.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 43.2 | < 0.02 | < 0.02 | < 0.02 | 19.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 43.3 | < 0.02 | < 0.02 | < 0.02 | 19.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 43.3 | 226.21 | 35.520 | 2.17 | 19.51 | 0.30 | 0.28 | 0.12 | 1.10 |
| 18 | 43.4 | < 0.02 | < 0.02 | < 0.02 | 19.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 43.5 | < 0.02 | < 0.02 | < 0.02 | 19.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 62.9 | < 0.02 | < 0.02 | < 0.02 | 18.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 62.9 | 221.70 | 35.528 | 3.38 | 18.58 | 0.36 | 0.28 | 0.15 | 1.29 |
| 12 | 82.8 | 182.44 | 35.455 | 8.07 | 17.45 | 0.64 | 0.08 | 0.12 | 2.42 |
| 13 | 82.9 | < 0.02 | < 0.02 | < 0.02 | 17.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 102.6 | 175.61 | 35.399 | 9.82 | 16.55 | 0.75 | < 0.02 | 0.06 | 2.94 |
| 11 | 102.7 | < 0.02 | < 0.02 | < 0.02 | 16.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 152.4 | 191.46 | 35.309 | 10.24 | 14.94 | 0.76 | < 0.02 | 0.03 | 3.03 |
| 9 | 152.4 | < 0.02 | < 0.02 | < 0.02 | 14.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 177.2 | 193.96 | 35.277 | 10.65 | 14.48 | 0.78 | < 0.02 | 0.03 | 3.13 |
| 6 | 202.1 | 194.59 | 35.230 | 11.40 | 14.01 | 0.83 | < 0.02 | 0.03 | 3.49 |
| 5 | 226.7 | 193.87 | 35.174 | 12.31 | 13.51 | 0.89 | < 0.02 | 0.03 | 3.87 |
| 4 | 251.4 | 196.15 | 35.147 | 12.67 | 13.23 | 0.90 | < 0.02 | 0.02 | 4.03 |
| 3 | 301.1 | 197.40 | 35.049 | 14.20 | 12.37 | 1.00 | < 0.02 | 0.02 | 4.72 |
| 2 | 350.9 | 200.17 | 34.969 | 15.52 | 11.66 | 1.09 | < 0.02 | 0.02 | 5.40 |
| 1 | 371.9 | 201.26 | 34.924 | 16.26 | 11.09 | 1.14 | < 0.02 | 0.03 | 5.80 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |