Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 56
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-14 04:11 to 2024-02-14 07:26 UTC
Where: 54° 23.2' S 115° 01.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 5.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 8.4 | 317.90 | 33.854 | 24.86 | 5.03 | 1.64 | 0.40 | 0.27 | 4.43 |
33 | 20 | < 0.02 | < 0.02 | < 0.02 | 5.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 20.1 | 317.72 | 33.854 | 24.84 | 5.03 | 1.64 | 0.40 | 0.26 | 4.42 |
34 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 5.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 39.8 | 318.03 | 33.855 | 24.84 | 5.01 | 1.65 | 0.41 | 0.26 | 4.46 |
31 | 39.9 | < 0.02 | < 0.02 | < 0.02 | 5.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 64.7 | < 0.02 | < 0.02 | < 0.02 | 4.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 64.9 | 318.48 | 33.855 | 24.93 | 4.95 | 1.66 | 0.44 | 0.26 | 4.62 |
28 | 65 | < 0.02 | < 0.02 | < 0.02 | 4.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 89.9 | < 0.02 | < 0.02 | < 0.02 | 4.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 89.9 | 345.23 | 33.877 | 25.43 | 4.28 | 1.75 | 0.67 | 0.26 | 6.70 |
22 | 125 | 331.56 | 33.925 | 28.70 | 1.90 | 2.07 | 0.56 | 0.43 | 23.08 |
24 | 125.1 | < 0.02 | < 0.02 | < 0.02 | 1.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 125.2 | < 0.02 | < 0.02 | < 0.02 | 1.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 175.1 | 301.15 | 34.047 | 31.27 | 1.40 | 2.15 | < 0.02 | 0.03 | 33.79 |
19 | 285.2 | 212.10 | 34.334 | < 0.02 | 2.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 285.3 | < 0.02 | < 0.02 | < 0.02 | 2.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 469.4 | 177.39 | 34.550 | 35.19 | 2.35 | 2.41 | < 0.02 | 0.02 | 73.38 |
17 | 580 | < 0.02 | < 0.02 | < 0.02 | 2.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 580 | 175.70 | 34.606 | 34.62 | 2.32 | 2.37 | < 0.02 | 0.02 | 76.87 |
15 | 920.1 | < 0.02 | < 0.02 | < 0.02 | 2.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 920.1 | 187.08 | 34.710 | 32.35 | 2.13 | 2.23 | < 0.02 | < 0.02 | 82.32 |
13 | 1220.3 | 196.60 | 34.739 | 31.36 | 1.92 | 2.16 | < 0.02 | < 0.02 | 86.60 |
12 | 1470.2 | < 0.02 | < 0.02 | < 0.02 | 1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 1470.2 | 223.57 | 34.744 | 31.17 | 1.71 | 2.16 | < 0.02 | < 0.02 | 92.55 |
10 | 1830.4 | < 0.02 | < 0.02 | < 0.02 | 1.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 1830.4 | 206.47 | 34.734 | 31.51 | 1.38 | 2.18 | < 0.02 | < 0.02 | 101.97 |
8 | 2330.2 | 211.74 | 34.713 | 32.29 | 0.96 | 2.24 | < 0.02 | < 0.02 | 114.64 |
7 | 2780.5 | 217.99 | 34.695 | 32.82 | 0.61 | 2.29 | < 0.02 | 0.02 | 124.78 |
6 | 3330 | < 0.02 | < 0.02 | < 0.02 | 0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3330.1 | 224.24 | 34.681 | 33.05 | 0.35 | 2.29 | < 0.02 | 0.02 | 133.17 |
3 | 3930.6 | 228.71 | 34.673 | 33.09 | 0.24 | 2.30 | < 0.02 | 0.02 | 138.62 |
4 | 3930.6 | < 0.02 | < 0.02 | < 0.02 | 0.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 4191.5 | 228.84 | 34.673 | 33.14 | 0.25 | 2.30 | < 0.02 | < 0.02 | 140.27 |
2 | 4191.6 | < 0.02 | < 0.02 | < 0.02 | 0.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |