Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-01-23 00:18 to 2024-01-23 02:51 UTC
Where: 62° 51.2' S 139° 59.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.3 | 360.59 | 33.793 | 23.98 | 1.03 | 1.46 | 0.06 | 0.28 | 20.83 |
| 36 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 14.7 | < 0.02 | < 0.02 | < 0.02 | 1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 14.7 | 362.56 | 33.792 | 23.94 | 1.02 | 1.45 | 0.06 | 0.29 | 20.81 |
| 32 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 0.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 30.2 | 359.12 | 33.798 | 24.06 | 0.96 | 1.49 | 0.16 | 0.27 | 21.12 |
| 29 | 45.2 | 325.76 | 34.010 | 29.08 | -0.39 | 2.16 | 1.19 | 0.22 | 43.35 |
| 30 | 45.2 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 55.2 | 285.43 | 34.199 | 32.53 | -0.42 | 2.32 | 0.63 | 0.20 | 57.18 |
| 28 | 55.2 | < 0.02 | < 0.02 | < 0.02 | -0.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 99.9 | 193.25 | 34.503 | 35.54 | 1.53 | 2.45 | < 0.02 | 0.05 | 74.52 |
| 25 | 155.2 | < 0.02 | < 0.02 | < 0.02 | 1.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 155.3 | 177.13 | 34.606 | 35.22 | 1.97 | 2.42 | < 0.02 | 0.02 | 80.56 |
| 23 | 199.9 | < 0.02 | < 0.02 | < 0.02 | 2.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 199.9 | 177.26 | 34.642 | 34.58 | 2.03 | 2.38 | < 0.02 | 0.02 | 82.08 |
| 20 | 300.1 | 182.22 | 34.683 | 33.61 | 1.97 | 2.31 | < 0.02 | < 0.02 | 84.30 |
| 21 | 300.1 | < 0.02 | < 0.02 | < 0.02 | 1.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 530.3 | 192.94 | 34.729 | 32.20 | 1.85 | 2.22 | < 0.02 | < 0.02 | 87.78 |
| 17 | 790.3 | 200.89 | 34.736 | 31.74 | 1.58 | 2.19 | < 0.02 | < 0.02 | 93.89 |
| 18 | 790.4 | < 0.02 | < 0.02 | < 0.02 | 1.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 930.3 | < 0.02 | < 0.02 | < 0.02 | 1.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 930.3 | 203.74 | 34.735 | 31.74 | 1.45 | 2.19 | < 0.02 | < 0.02 | 97.96 |
| 13 | 1210.4 | 208.16 | 34.724 | 32.08 | 1.18 | 2.22 | < 0.02 | < 0.02 | 105.19 |
| 14 | 1210.5 | < 0.02 | < 0.02 | < 0.02 | 1.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1450.3 | 212.18 | 34.710 | 32.45 | 0.92 | 2.25 | < 0.02 | < 0.02 | 110.58 |
| 10 | 1709.5 | 213.43 | 34.705 | 32.80 | 0.77 | 2.27 | < 0.02 | < 0.02 | 117.79 |
| 11 | 1709.6 | < 0.02 | < 0.02 | < 0.02 | 0.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 2260.3 | < 0.02 | < 0.02 | < 0.02 | 0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2260.3 | 222.41 | 34.684 | 33.19 | 0.36 | 2.30 | < 0.02 | < 0.02 | 126.84 |
| 7 | 2700.4 | 229.78 | 34.674 | 33.19 | 0.13 | 2.31 | < 0.02 | < 0.02 | 129.43 |
| 5 | 3020.7 | 236.88 | 34.664 | 33.12 | -0.05 | 2.30 | < 0.02 | < 0.02 | 128.76 |
| 6 | 3020.8 | < 0.02 | < 0.02 | < 0.02 | -0.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3200.4 | 242.64 | 34.659 | 32.95 | -0.17 | 2.29 | < 0.02 | < 0.02 | 118.03 |
| 4 | 3200.5 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3257 | 242.91 | 34.658 | 32.89 | -0.16 | 2.28 | < 0.02 | < 0.02 | 117.86 |
| 2 | 3257.1 | < 0.02 | < 0.02 | < 0.02 | -0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |