Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751
When: 2023-06-12 17:59 to 2023-06-12 21:23 UTC
Where: 52° 39.6' S 142° 23.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 25.1 | < 0.02 | 33.989 | 21.10 | 6.00 | 1.49 | 0.11 | 0.28 | 3.81 |
| 35 | 25.5 | 303.38 | < 0.02 | 21.13 | 6.00 | 1.49 | 0.11 | 0.28 | 3.88 |
| 34 | 50.4 | < 0.02 | < 0.02 | 21.12 | 6.01 | 1.50 | 0.12 | 0.28 | 3.85 |
| 33 | 80 | < 0.02 | < 0.02 | 21.23 | 5.99 | 1.50 | 0.12 | 0.28 | 3.76 |
| 32 | 100.5 | < 0.02 | < 0.02 | 21.59 | 5.82 | 1.53 | 0.14 | 0.27 | 3.99 |
| 31 | 150.5 | < 0.02 | 33.999 | 22.41 | 5.75 | 1.57 | 0.10 | 0.21 | 5.28 |
| 30 | 150.6 | 300.21 | < 0.02 | 22.46 | 5.76 | 1.57 | 0.10 | 0.21 | 5.16 |
| 29 | 200.3 | < 0.02 | < 0.02 | 21.77 | 6.70 | 1.52 | < 0.02 | 0.05 | 7.60 |
| 28 | 300.9 | < 0.02 | < 0.02 | 26.83 | 5.34 | 1.84 | < 0.02 | < 0.02 | 15.72 |
| 27 | 400.2 | < 0.02 | < 0.02 | 29.21 | 4.67 | 1.99 | < 0.02 | < 0.02 | 21.58 |
| 26 | 500.4 | < 0.02 | < 0.02 | 31.09 | 3.98 | 2.13 | < 0.02 | < 0.02 | 29.06 |
| 25 | 600.2 | < 0.02 | < 0.02 | 32.45 | 3.56 | 2.22 | < 0.02 | < 0.02 | 36.13 |
| 23 | 700.3 | 206.11 | < 0.02 | 33.76 | 3.32 | 2.31 | < 0.02 | < 0.02 | 45.25 |
| 24 | 700.3 | < 0.02 | 34.214 | 33.74 | 3.32 | 2.31 | < 0.02 | < 0.02 | 45.28 |
| 22 | 800.4 | < 0.02 | < 0.02 | 34.49 | 3.17 | 2.36 | < 0.02 | < 0.02 | 52.94 |
| 21 | 900.1 | < 0.02 | < 0.02 | 34.88 | 2.99 | 2.40 | < 0.02 | < 0.02 | 61.33 |
| 20 | 999.1 | < 0.02 | 34.515 | 34.98 | 2.86 | 2.41 | < 0.02 | < 0.02 | 67.22 |
| 19 | 999.2 | 178.02 | < 0.02 | 34.91 | 2.86 | 2.41 | < 0.02 | < 0.02 | 67.32 |
| 18 | 1150.3 | < 0.02 | 34.574 | 34.55 | 2.67 | 2.38 | < 0.02 | < 0.02 | 71.68 |
| 17 | 1150.6 | 176.99 | < 0.02 | 34.48 | 2.67 | 2.38 | < 0.02 | < 0.02 | 71.89 |
| 16 | 1300.4 | < 0.02 | < 0.02 | 33.81 | 2.55 | 2.33 | < 0.02 | < 0.02 | 75.34 |
| 15 | 1400.1 | < 0.02 | < 0.02 | 33.26 | 2.47 | 2.29 | < 0.02 | < 0.02 | 76.57 |
| 14 | 1500.2 | < 0.02 | < 0.02 | 32.71 | 2.40 | 2.25 | < 0.02 | < 0.02 | 78.20 |
| 13 | 1600.4 | < 0.02 | < 0.02 | 32.20 | 2.32 | 2.22 | < 0.02 | < 0.02 | 79.51 |
| 12 | 1700.5 | < 0.02 | < 0.02 | 31.81 | 2.23 | 2.19 | < 0.02 | < 0.02 | 81.41 |
| 11 | 1800.6 | < 0.02 | < 0.02 | 31.58 | 2.18 | 2.17 | < 0.02 | < 0.02 | 82.85 |
| 10 | 2000.3 | < 0.02 | < 0.02 | 31.26 | 2.00 | 2.15 | < 0.02 | < 0.02 | 87.63 |
| 8 | 2150.6 | 201.42 | < 0.02 | 31.23 | 1.86 | 2.16 | < 0.02 | < 0.02 | 92.00 |
| 9 | 2150.6 | < 0.02 | 34.744 | 31.30 | 1.86 | 2.16 | < 0.02 | < 0.02 | 92.03 |
| 7 | 2300.6 | < 0.02 | < 0.02 | 31.39 | 1.71 | 2.16 | < 0.02 | < 0.02 | 96.60 |
| 6 | 2399.3 | < 0.02 | < 0.02 | 31.48 | 1.62 | 2.18 | 0.03 | < 0.02 | 99.20 |
| 5 | 2600.5 | < 0.02 | < 0.02 | 31.67 | 1.43 | 2.19 | < 0.02 | < 0.02 | 104.47 |
| 4 | 2800.1 | < 0.02 | < 0.02 | 32.10 | 1.18 | 2.22 | < 0.02 | < 0.02 | 112.50 |
| 3 | 3000.6 | < 0.02 | < 0.02 | 32.41 | 1.01 | 2.24 | < 0.02 | < 0.02 | 118.48 |
| 2 | 3250.9 | < 0.02 | 34.706 | 32.60 | 0.88 | 2.26 | < 0.02 | < 0.02 | 123.54 |
| 1 | 3251.1 | 214.51 | < 0.02 | < 0.02 | 0.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |