Deployment Details
Survey: - IN2023_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer - CTD 24 -CST-1421DR
When: 2023-05-22 20:10 to 2023-05-22 20:55 UTC
Where: 47° 27.2' S 143° 42.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Temperature (deg C) |
---|---|---|---|---|
31 | 47.8 | < 0.02 | < 0.02 | 9.89 |
30 | 47.9 | < 0.02 | < 0.02 | 9.89 |
26 | 47.9 | < 0.02 | < 0.02 | 9.89 |
27 | 47.9 | < 0.02 | < 0.02 | 9.89 |
36 | 48 | < 0.02 | < 0.02 | 9.89 |
28 | 48.1 | < 0.02 | < 0.02 | 9.89 |
25 | 48.1 | < 0.02 | < 0.02 | 9.89 |
32 | 48.1 | < 0.02 | < 0.02 | 9.89 |
24 | 48.1 | 278.82 | 34.599 | 9.89 |
29 | 48.2 | < 0.02 | < 0.02 | 9.89 |
35 | 48.5 | < 0.02 | < 0.02 | 9.89 |
33 | 48.6 | < 0.02 | < 0.02 | 9.89 |
34 | 48.9 | < 0.02 | < 0.02 | 9.89 |
21 | 199.3 | < 0.02 | < 0.02 | 10.49 |
22 | 199.3 | < 0.02 | < 0.02 | 10.48 |
15 | 199.3 | < 0.02 | < 0.02 | 10.49 |
16 | 199.3 | < 0.02 | < 0.02 | 10.49 |
13 | 199.4 | < 0.02 | < 0.02 | 10.49 |
20 | 199.5 | < 0.02 | < 0.02 | 10.48 |
14 | 199.5 | 241.17 | 34.826 | 10.49 |
23 | 199.8 | < 0.02 | < 0.02 | 10.48 |
17 | 199.8 | < 0.02 | < 0.02 | 10.48 |
19 | 199.8 | < 0.02 | < 0.02 | 10.48 |
18 | 200.1 | < 0.02 | < 0.02 | 10.47 |
6 | 300.4 | < 0.02 | < 0.02 | 9.49 |
7 | 300.4 | < 0.02 | < 0.02 | 9.49 |
3 | 300.5 | < 0.02 | < 0.02 | 9.49 |
1 | 300.5 | 264.48 | 34.652 | 9.49 |
12 | 300.7 | < 0.02 | < 0.02 | 9.49 |
10 | 300.7 | < 0.02 | < 0.02 | 9.49 |
11 | 300.8 | < 0.02 | < 0.02 | 9.49 |
2 | 300.9 | < 0.02 | < 0.02 | 9.49 |
8 | 300.9 | < 0.02 | < 0.02 | 9.49 |
9 | 300.9 | < 0.02 | < 0.02 | 9.49 |
5 | 301 | < 0.02 | < 0.02 | 9.49 |
4 | 301.2 | < 0.02 | < 0.02 | 9.49 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |