Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: CTD 24 - SN 1332,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer - CTD 24 -CST-1421DR
When: 2023-05-12 00:31 to 2023-05-12 01:12 UTC
Where: 44° 17.8' S 147° 04.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1 | 1004.2 | 192.53 | 34.440 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1004.4 | 191.91 | 34.439 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 1004.6 | 192.62 | 34.440 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1004.7 | 191.77 | 34.440 | < 0.02 | 5.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1004.8 | 191.77 | 34.440 | < 0.02 | 5.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1004.8 | 192.09 | 34.439 | < 0.02 | 5.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1004.8 | 192.09 | 34.439 | < 0.02 | 5.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 1004.9 | 192.27 | 34.450 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1004.9 | 192.27 | 34.440 | < 0.02 | 5.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1005.1 | 192.35 | 34.439 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1005.2 | 192.09 | 34.441 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 1005.3 | 192.09 | 34.439 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1005.4 | 192.00 | 34.439 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 1005.4 | 192.67 | 34.439 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 1005.5 | 192.18 | 34.440 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1005.5 | 192.18 | 34.439 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 1005.6 | 191.55 | 34.441 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 1005.7 | 191.77 | 34.439 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1005.7 | 192.22 | 34.441 | < 0.02 | 5.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 1005.7 | 192.40 | 34.440 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 1005.8 | 191.82 | 34.441 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 1005.9 | 191.73 | 34.440 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 1006.1 | 192.13 | 34.441 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 1006.1 | 192.49 | 34.440 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 1006.1 | 192.04 | 34.440 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 1006.1 | 191.91 | 34.443 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 1006.2 | 191.95 | 34.440 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 1006.2 | 192.09 | 34.440 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 1006.3 | 191.86 | 34.442 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 1006.3 | 191.73 | 34.439 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 1006.3 | 191.82 | 34.441 | < 0.02 | 5.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 1006.4 | 191.69 | 34.440 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 1006.4 | 191.91 | 34.441 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 1006.5 | 192.22 | 34.440 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 1006.5 | 191.77 | 34.443 | < 0.02 | 5.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 1006.9 | 191.60 | 34.440 | < 0.02 | 5.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |