Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 42
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-25 14:09 to 2022-10-25 15:12 UTC
Where: 13° 39.2' S 96° 42.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
32 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 7 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 27.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 27.26 | 0.04 | < 0.02 | < 0.02 | 1.37 |
24 | 20.6 | < 0.02 | < 0.02 | < 0.02 | 27.26 | 0.04 | < 0.02 | < 0.02 | 1.39 |
23 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 26.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 26.91 | 0.06 | < 0.02 | < 0.02 | 1.28 |
21 | 70.8 | < 0.02 | < 0.02 | 0.02 | 26.54 | 0.08 | < 0.02 | 0.02 | 1.35 |
19 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 26.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 80.7 | 206.87 | 33.991 | 0.04 | 26.52 | 0.08 | 0.02 | 0.03 | 1.31 |
20 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 26.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 110.6 | 201.38 | 34.002 | 0.29 | 26.42 | 0.13 | 0.42 | 0.15 | 1.38 |
15 | 200.3 | < 0.02 | < 0.02 | 15.75 | 19.03 | 1.12 | < 0.02 | 0.02 | 18.40 |
16 | 200.4 | < 0.02 | < 0.02 | < 0.02 | 19.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 300.4 | 103.52 | 34.651 | 24.12 | 13.11 | 1.71 | < 0.02 | < 0.02 | 33.66 |
13 | 400.2 | 131.17 | 34.802 | 23.72 | 10.88 | 1.67 | < 0.02 | < 0.02 | 28.64 |
11 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 9.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 500.6 | 136.31 | 34.695 | 27.02 | 9.18 | 1.88 | < 0.02 | < 0.02 | 31.31 |
12 | 500.8 | < 0.02 | < 0.02 | < 0.02 | 9.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 750.4 | 85.93 | 34.659 | 35.39 | 7.00 | 2.55 | < 0.02 | < 0.02 | 69.47 |
6 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1000.2 | < 0.02 | < 0.02 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1000.3 | 91.69 | 34.643 | 36.78 | 5.47 | 2.69 | < 0.02 | < 0.02 | 93.55 |
8 | 1000.4 | < 0.02 | < 0.02 | < 0.02 | 5.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1312.4 | < 0.02 | < 0.02 | < 0.02 | 4.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1312.4 | 103.30 | 34.659 | 36.99 | 4.23 | 2.72 | < 0.02 | < 0.02 | 107.66 |
3 | 1312.5 | < 0.02 | < 0.02 | < 0.02 | 4.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1312.8 | < 0.02 | < 0.02 | < 0.02 | 4.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |