Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 36
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-22 18:39 to 2022-10-22 19:02 UTC
Where: 13° 11.3' S 96° 09.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 5.4 | < 0.02 | < 0.02 | 0.03 | 27.46 | 0.04 | < 0.02 | < 0.02 | 1.55 |
| 29 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 10.2 | < 0.02 | < 0.02 | 0.03 | 27.46 | 0.04 | < 0.02 | < 0.02 | 1.55 |
| 22 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 19.6 | 202.98 | 33.733 | 0.02 | 27.47 | 0.04 | < 0.02 | < 0.02 | 1.52 |
| 20 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 27.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 20.3 | < 0.02 | < 0.02 | < 0.02 | 27.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 30.2 | < 0.02 | < 0.02 | 0.02 | 27.47 | 0.04 | < 0.02 | < 0.02 | 1.55 |
| 17 | 30.7 | < 0.02 | < 0.02 | < 0.02 | 27.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 40.3 | < 0.02 | < 0.02 | < 0.02 | 27.47 | 0.04 | < 0.02 | < 0.02 | 1.57 |
| 15 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 27.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 50.4 | 200.80 | 33.733 | < 0.02 | 27.48 | 0.04 | < 0.02 | < 0.02 | 1.58 |
| 11 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 27.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 60.6 | 202.72 | 33.734 | < 0.02 | 27.47 | 0.04 | < 0.02 | < 0.02 | 1.58 |
| 8 | 70.1 | 203.70 | 33.734 | 0.03 | 27.48 | 0.04 | < 0.02 | 0.02 | 1.58 |
| 9 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 27.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 80.7 | 203.83 | 33.870 | 0.03 | 27.08 | 0.07 | < 0.02 | 0.02 | 1.58 |
| 7 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 27.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 86.6 | 202.72 | 33.956 | 0.18 | 26.79 | 0.09 | < 0.02 | 0.03 | 1.64 |
| 3 | 86.8 | < 0.02 | < 0.02 | < 0.02 | 26.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 86.8 | < 0.02 | < 0.02 | < 0.02 | 26.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 86.8 | < 0.02 | < 0.02 | < 0.02 | 26.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |