Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 35
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-22 16:19 to 2022-10-22 16:50 UTC
Where: 13° 11.0' S 96° 08.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 27 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.52 | 0.03 | < 0.02 | < 0.02 | 1.57 |
| 36 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 27.50 | 0.03 | < 0.02 | < 0.02 | 1.58 |
| 14 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 27.45 | 0.03 | < 0.02 | < 0.02 | 1.59 |
| 15 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 80.5 | 204.55 | 33.925 | 0.04 | 26.87 | 0.07 | < 0.02 | 0.02 | 1.53 |
| 11 | 90 | < 0.02 | < 0.02 | < 0.02 | 26.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 90.1 | 197.36 | 33.997 | 0.59 | 26.77 | 0.12 | < 0.02 | 0.09 | 1.84 |
| 12 | 90.4 | < 0.02 | < 0.02 | < 0.02 | 26.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 121.2 | 132.64 | 34.289 | 10.52 | 23.28 | 0.78 | < 0.02 | 0.04 | 11.38 |
| 7 | 201 | 114.60 | 34.590 | 18.63 | 17.09 | 1.33 | < 0.02 | 0.02 | 23.66 |
| 8 | 201 | < 0.02 | 34.587 | < 0.02 | 17.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 300.2 | 99.06 | 34.655 | 25.84 | 12.23 | 1.83 | < 0.02 | < 0.02 | 36.39 |
| 3 | 389.7 | < 0.02 | < 0.02 | < 0.02 | 10.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 389.7 | < 0.02 | < 0.02 | < 0.02 | 10.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 389.7 | 101.78 | 34.676 | 27.62 | 10.57 | 1.97 | < 0.02 | < 0.02 | 39.22 |
| 4 | 389.8 | < 0.02 | < 0.02 | < 0.02 | 10.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 389.8 | < 0.02 | < 0.02 | < 0.02 | 10.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |