Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 33
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-22 07:08 to 2022-10-22 07:28 UTC
Where: 13° 10.2' S 96° 11.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 18 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 27.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 27.48 | 0.03 | < 0.02 | < 0.02 | 1.51 |
| 34 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 27.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 20.4 | 206.56 | 33.722 | < 0.02 | 27.45 | 0.04 | < 0.02 | < 0.02 | 1.57 |
| 15 | 69.9 | < 0.02 | < 0.02 | < 0.02 | 27.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 70.1 | 207.45 | 33.860 | < 0.02 | 27.11 | 0.05 | < 0.02 | < 0.02 | 1.55 |
| 13 | 70.1 | < 0.02 | < 0.02 | < 0.02 | 27.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 70.1 | < 0.02 | < 0.02 | < 0.02 | 27.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 95.3 | < 0.02 | < 0.02 | < 0.02 | 26.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 95.4 | < 0.02 | < 0.02 | < 0.02 | 26.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 95.4 | 144.57 | 34.309 | 6.76 | 26.10 | 0.56 | < 0.02 | 0.06 | 6.48 |
| 8 | 120.1 | 138.14 | 34.250 | 8.89 | 24.52 | 0.68 | < 0.02 | 0.04 | 9.22 |
| 6 | 200.3 | 113.39 | 34.581 | 18.27 | 17.32 | 1.32 | < 0.02 | 0.02 | 23.29 |
| 7 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 17.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 240.3 | 106.34 | 34.625 | 21.99 | 14.05 | 1.59 | < 0.02 | < 0.02 | 30.37 |
| 5 | 240.3 | < 0.02 | < 0.02 | < 0.02 | 14.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 240.4 | < 0.02 | < 0.02 | < 0.02 | 14.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 240.4 | < 0.02 | < 0.02 | < 0.02 | 14.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 240.4 | < 0.02 | < 0.02 | < 0.02 | 14.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |