Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 29
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-21 00:03 to 2022-10-21 01:03 UTC
Where: 13° 12.8' S 96° 06.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
26 | 8 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 27.24 | 0.03 | 0.03 | < 0.02 | 1.70 |
30 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 27.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 20 | < 0.02 | < 0.02 | < 0.02 | 27.24 | 0.03 | 0.03 | < 0.02 | 1.70 |
23 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 27.23 | 0.03 | 0.03 | < 0.02 | 1.70 |
22 | 70.3 | < 0.02 | < 0.02 | < 0.02 | 26.76 | 0.06 | 0.03 | < 0.02 | 1.38 |
19 | 95.4 | 198.12 | 33.961 | 0.37 | 26.60 | 0.11 | 0.04 | 0.22 | 1.59 |
21 | 95.5 | < 0.02 | < 0.02 | < 0.02 | 26.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 95.5 | < 0.02 | < 0.02 | < 0.02 | 26.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 105.4 | < 0.02 | < 0.02 | 2.83 | 26.22 | 0.28 | 0.07 | 0.24 | 3.76 |
18 | 105.5 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 116.1 | < 0.02 | < 0.02 | 7.31 | 25.02 | 0.58 | 0.03 | 0.06 | 7.61 |
15 | 151.2 | < 0.02 | < 0.02 | 12.35 | 21.78 | 0.92 | 0.03 | 0.02 | 13.72 |
13 | 200.6 | 114.15 | 34.544 | 17.40 | 18.07 | 1.27 | 0.03 | < 0.02 | 21.61 |
14 | 200.7 | < 0.02 | < 0.02 | < 0.02 | 18.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 301.2 | 99.15 | 34.638 | 26.12 | 11.79 | 1.90 | 0.03 | < 0.02 | 37.94 |
11 | 401.9 | 104.06 | 34.704 | 27.72 | 10.34 | 1.99 | 0.03 | < 0.02 | 38.19 |
10 | 450 | 121.12 | 34.719 | 27.40 | 9.61 | 1.95 | 0.03 | < 0.02 | 34.05 |
8 | 500.4 | < 0.02 | < 0.02 | < 0.02 | 8.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 500.5 | 111.74 | 34.690 | 29.77 | 8.94 | 2.13 | 0.03 | < 0.02 | 40.68 |
9 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 8.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 750.2 | 82.22 | 34.658 | 35.66 | 6.94 | 2.63 | 0.03 | < 0.02 | 72.70 |
6 | 750.2 | < 0.02 | < 0.02 | < 0.02 | 6.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 813.5 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 813.5 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 813.5 | < 0.02 | < 0.02 | < 0.02 | 6.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 813.5 | 83.61 | 34.648 | 36.21 | 6.37 | 2.69 | 0.03 | < 0.02 | 81.24 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |