Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 27
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-20 07:03 to 2022-10-20 08:00 UTC
Where: 13° 15.0' S 96° 05.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 6.9 | < 0.02 | < 0.02 | 0.02 | 27.52 | 0.03 | < 0.02 | < 0.02 | 1.83 |
| 30 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 7 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7 | < 0.02 | < 0.02 | < 0.02 | 27.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 27.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 19.5 | < 0.02 | < 0.02 | 0.02 | 27.29 | 0.03 | < 0.02 | < 0.02 | 1.84 |
| 18 | 49.1 | < 0.02 | < 0.02 | 0.03 | 26.89 | 0.07 | < 0.02 | < 0.02 | 1.50 |
| 19 | 49.2 | < 0.02 | < 0.02 | < 0.02 | 26.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 68.8 | < 0.02 | < 0.02 | 0.66 | 26.67 | 0.13 | 0.02 | 0.30 | 2.06 |
| 14 | 79.3 | < 0.02 | < 0.02 | 1.35 | 26.67 | 0.17 | < 0.02 | 0.34 | 2.55 |
| 15 | 79.4 | < 0.02 | < 0.02 | < 0.02 | 26.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 79.5 | < 0.02 | < 0.02 | < 0.02 | 26.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 90.6 | 168.46 | 34.009 | 4.36 | 26.16 | 0.37 | < 0.02 | 0.17 | 4.96 |
| 12 | 203.2 | < 0.02 | < 0.02 | < 0.02 | 17.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 203.2 | 113.39 | 34.580 | 18.49 | 17.21 | 1.34 | < 0.02 | < 0.02 | 23.51 |
| 10 | 300.6 | 99.64 | 34.661 | 25.17 | 12.56 | 1.82 | < 0.02 | < 0.02 | 35.14 |
| 9 | 400.2 | 105.27 | 34.722 | 27.45 | 10.53 | 1.96 | < 0.02 | < 0.02 | 37.04 |
| 7 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 9.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 500.6 | 113.62 | 34.697 | 29.38 | 9.13 | 2.08 | < 0.02 | < 0.02 | 39.23 |
| 5 | 752.2 | 84.63 | 34.657 | 35.54 | 6.87 | 2.61 | < 0.02 | < 0.02 | 73.17 |
| 1 | 1012.2 | 91.82 | 34.639 | 36.84 | 5.35 | 2.74 | < 0.02 | < 0.02 | 95.66 |
| 2 | 1012.4 | < 0.02 | < 0.02 | < 0.02 | 5.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1012.4 | < 0.02 | < 0.02 | < 0.02 | 5.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1012.4 | < 0.02 | < 0.02 | < 0.02 | 5.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |