Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 26
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-20 01:53 to 2022-10-20 03:12 UTC
Where: 13° 16.8' S 96° 04.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 27.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 27.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.21 | 0.02 | < 0.02 | < 0.02 | 1.58 |
| 34 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 20.3 | < 0.02 | < 0.02 | < 0.02 | 27.16 | 0.02 | < 0.02 | < 0.02 | 1.63 |
| 26 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 27.17 | 0.03 | < 0.02 | < 0.02 | 1.59 |
| 27 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 27.01 | 0.06 | < 0.02 | < 0.02 | 1.53 |
| 23 | 75.1 | < 0.02 | < 0.02 | < 0.02 | 26.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 75.2 | 202.81 | 33.954 | 0.05 | 26.78 | 0.08 | < 0.02 | 0.04 | 1.68 |
| 24 | 75.3 | < 0.02 | < 0.02 | < 0.02 | 26.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 85.2 | < 0.02 | < 0.02 | < 0.02 | 26.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 85.3 | < 0.02 | < 0.02 | 0.10 | 26.84 | 0.08 | < 0.02 | 0.04 | 1.47 |
| 19 | 95.3 | < 0.02 | < 0.02 | < 0.02 | 26.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 95.3 | < 0.02 | < 0.02 | 0.88 | 26.77 | 0.14 | < 0.02 | 0.26 | 2.15 |
| 17 | 120.5 | < 0.02 | < 0.02 | < 0.02 | 24.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 120.6 | 141.35 | 34.253 | 8.22 | 24.71 | 0.64 | < 0.02 | 0.06 | 8.60 |
| 14 | 200.9 | < 0.02 | < 0.02 | 17.12 | 18.10 | 1.23 | < 0.02 | 0.02 | 21.15 |
| 15 | 200.9 | < 0.02 | < 0.02 | < 0.02 | 18.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 300.3 | < 0.02 | < 0.02 | 24.87 | 12.73 | 1.78 | < 0.02 | < 0.02 | 35.27 |
| 12 | 399.9 | 102.54 | 34.724 | 27.75 | 10.50 | 1.95 | < 0.02 | < 0.02 | 37.24 |
| 11 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 500.7 | < 0.02 | < 0.02 | < 0.02 | 8.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 500.8 | 116.92 | 34.688 | 29.38 | 8.98 | 2.06 | < 0.02 | < 0.02 | 38.63 |
| 8 | 751 | 82.44 | 34.658 | 36.13 | 6.72 | 2.63 | < 0.02 | < 0.02 | 75.28 |
| 6 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 5.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1000.3 | 90.17 | 34.631 | 37.22 | 5.23 | 2.73 | < 0.02 | < 0.02 | 99.59 |
| 7 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 5.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1470.4 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1470.9 | < 0.02 | < 0.02 | < 0.02 | 3.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1471 | < 0.02 | < 0.02 | < 0.02 | 3.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1471.2 | 110.22 | 34.684 | 37.39 | 3.76 | 2.74 | < 0.02 | < 0.02 | 112.73 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |