Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-18 19:51 to 2022-10-18 22:14 UTC
Where: 12° 58.4' S 95° 29.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 27.30 | 0.05 | < 0.02 | < 0.02 | 1.52 |
| 34 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 27.31 | 0.05 | < 0.02 | < 0.02 | 1.52 |
| 33 | 50.9 | < 0.02 | < 0.02 | < 0.02 | 27.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 26.97 | 0.05 | < 0.02 | < 0.02 | 1.43 |
| 31 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 26.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 70.7 | < 0.02 | < 0.02 | < 0.02 | 26.53 | 0.06 | < 0.02 | < 0.02 | 1.60 |
| 29 | 85.1 | < 0.02 | < 0.02 | < 0.02 | 26.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 85.2 | < 0.02 | < 0.02 | < 0.02 | 26.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 85.2 | 204.19 | 33.962 | 0.06 | 26.48 | 0.08 | 0.04 | 0.03 | 1.72 |
| 26 | 100.9 | < 0.02 | < 0.02 | < 0.02 | 26.49 | 0.09 | 0.08 | 0.02 | 0.99 |
| 25 | 110.7 | < 0.02 | < 0.02 | 2.90 | 26.10 | 0.29 | < 0.02 | 0.21 | 3.99 |
| 24 | 150.1 | < 0.02 | < 0.02 | 12.37 | 21.77 | 0.91 | < 0.02 | 0.03 | 13.96 |
| 22 | 201 | < 0.02 | < 0.02 | 18.88 | 16.86 | 1.36 | < 0.02 | 0.02 | 24.12 |
| 23 | 201 | < 0.02 | < 0.02 | < 0.02 | 16.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 301.1 | < 0.02 | < 0.02 | 26.00 | 12.07 | 1.87 | < 0.02 | < 0.02 | 36.95 |
| 20 | 351 | < 0.02 | < 0.02 | 28.47 | 11.09 | 2.02 | < 0.02 | < 0.02 | 38.38 |
| 19 | 400.4 | < 0.02 | < 0.02 | 29.13 | 10.55 | 2.06 | < 0.02 | < 0.02 | 38.50 |
| 16 | 500.9 | 107.72 | 34.711 | 29.39 | 9.35 | 2.07 | < 0.02 | < 0.02 | 38.38 |
| 18 | 500.9 | < 0.02 | < 0.02 | < 0.02 | 9.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 501 | < 0.02 | < 0.02 | < 0.02 | 9.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 751.1 | < 0.02 | < 0.02 | 35.77 | 6.96 | 2.61 | < 0.02 | < 0.02 | 72.59 |
| 13 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 5.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1000.6 | 89.46 | 34.633 | 37.05 | 5.32 | 2.73 | < 0.02 | < 0.02 | 97.33 |
| 14 | 1000.8 | < 0.02 | < 0.02 | < 0.02 | 5.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1500.6 | 110.63 | 34.693 | 37.23 | 3.71 | 2.74 | < 0.02 | < 0.02 | 112.72 |
| 9 | 2000 | < 0.02 | < 0.02 | < 0.02 | 2.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2000 | 142.96 | 34.731 | 35.92 | 2.59 | 2.61 | < 0.02 | < 0.02 | 120.07 |
| 10 | 2000.3 | < 0.02 | < 0.02 | < 0.02 | 2.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 2501 | 162.61 | 34.730 | 34.96 | 1.99 | 2.51 | < 0.02 | < 0.02 | 124.53 |
| 7 | 2501 | < 0.02 | < 0.02 | < 0.02 | 2.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 3001 | 174.09 | 34.724 | 34.65 | 1.59 | 2.47 | < 0.02 | < 0.02 | 130.93 |
| 3 | 3159.4 | < 0.02 | < 0.02 | < 0.02 | 1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 3159.5 | < 0.02 | < 0.02 | < 0.02 | 1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3159.5 | 176.95 | 34.722 | 34.58 | 1.53 | 2.46 | < 0.02 | < 0.02 | 131.59 |
| 2 | 3159.6 | < 0.02 | < 0.02 | < 0.02 | 1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |