Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-18 10:18 to 2022-10-18 11:50 UTC
Where: 12° 35.5' S 95° 25.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 26 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.39 | 0.03 | < 0.02 | < 0.02 | 1.66 |
| 30 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 27.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 20.3 | < 0.02 | < 0.02 | < 0.02 | 27.39 | 0.03 | < 0.02 | < 0.02 | 1.69 |
| 23 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 27.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 27.10 | 0.05 | < 0.02 | < 0.02 | 1.52 |
| 21 | 70.6 | < 0.02 | < 0.02 | < 0.02 | 26.85 | 0.07 | < 0.02 | 0.02 | 1.74 |
| 18 | 85.3 | 196.55 | 33.980 | 0.72 | 26.49 | 0.13 | < 0.02 | 0.32 | 2.11 |
| 19 | 85.4 | < 0.02 | < 0.02 | < 0.02 | 26.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 85.4 | < 0.02 | < 0.02 | < 0.02 | 26.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 100.2 | 174.22 | 34.158 | 3.42 | 26.06 | 0.33 | < 0.02 | 0.22 | 4.31 |
| 16 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 16.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 200.5 | < 0.02 | < 0.02 | 19.71 | 16.18 | 1.43 | < 0.02 | 0.02 | 25.82 |
| 14 | 300.7 | < 0.02 | < 0.02 | 25.23 | 12.19 | 1.83 | < 0.02 | 0.02 | 36.56 |
| 13 | 400 | 100.62 | 34.724 | 28.21 | 10.37 | 2.01 | < 0.02 | < 0.02 | 37.72 |
| 11 | 500 | < 0.02 | < 0.02 | < 0.02 | 9.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 500 | < 0.02 | < 0.02 | < 0.02 | 9.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 500.1 | 98.57 | 34.705 | 31.22 | 9.02 | 2.22 | < 0.02 | < 0.02 | 43.28 |
| 9 | 750.7 | 86.15 | 34.651 | 35.81 | 6.77 | 2.63 | < 0.02 | < 0.02 | 75.17 |
| 8 | 1000.5 | < 0.02 | < 0.02 | < 0.02 | 5.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1000.6 | 92.58 | 34.625 | 36.94 | 5.14 | 2.74 | < 0.02 | < 0.02 | 100.53 |
| 7 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 5.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1500.4 | 107.99 | 34.689 | 37.19 | 3.87 | 2.75 | < 0.02 | < 0.02 | 112.56 |
| 1 | 1901.3 | 139.34 | 34.732 | 35.98 | 2.76 | 2.63 | < 0.02 | < 0.02 | 118.38 |
| 4 | 1901.3 | < 0.02 | < 0.02 | < 0.02 | 2.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1901.4 | < 0.02 | < 0.02 | < 0.02 | 2.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1901.5 | < 0.02 | < 0.02 | < 0.02 | 2.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |