Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-16 17:31 to 2022-10-16 18:44 UTC
Where: 12° 14.3' S 96° 58.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 4 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 27.23 | 0.06 | < 0.02 | < 0.02 | 1.15 |
| 29 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 27.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 26.80 | 0.07 | < 0.02 | < 0.02 | 1.00 |
| 20 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 26.73 | 0.07 | < 0.02 | < 0.02 | 1.12 |
| 18 | 85.5 | < 0.02 | < 0.02 | < 0.02 | 26.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 85.5 | 202.23 | 34.031 | 0.16 | 26.63 | 0.10 | 0.03 | 0.06 | 1.43 |
| 19 | 85.6 | < 0.02 | < 0.02 | < 0.02 | 26.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 111.3 | 133.76 | 34.161 | 10.31 | 23.53 | 0.74 | < 0.02 | 0.06 | 11.13 |
| 15 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 16.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 200.4 | 118.49 | 34.492 | 18.96 | 16.04 | 1.35 | < 0.02 | < 0.02 | 26.18 |
| 13 | 301.4 | < 0.02 | < 0.02 | 26.54 | 11.59 | 1.87 | < 0.02 | < 0.02 | 38.98 |
| 12 | 402.2 | 101.92 | 34.681 | 28.74 | 9.93 | 2.00 | < 0.02 | < 0.02 | 41.34 |
| 9 | 500.5 | 116.43 | 34.692 | 29.30 | 8.93 | 2.03 | < 0.02 | < 0.02 | 38.08 |
| 10 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 500.7 | < 0.02 | < 0.02 | < 0.02 | 8.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 751.4 | 79.01 | 34.656 | 36.02 | 6.81 | 2.58 | < 0.02 | < 0.02 | 76.37 |
| 6 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 5.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 5.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1000.4 | 89.41 | 34.634 | 37.07 | 5.18 | 2.68 | < 0.02 | < 0.02 | 100.51 |
| 1 | 1346.2 | 105.67 | 34.682 | 37.16 | 3.91 | 2.70 | < 0.02 | < 0.02 | 112.92 |
| 4 | 1346.4 | < 0.02 | < 0.02 | < 0.02 | 3.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1346.5 | < 0.02 | < 0.02 | < 0.02 | 3.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1346.5 | < 0.02 | < 0.02 | < 0.02 | 3.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |