Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-16 11:50 to 2022-10-16 12:46 UTC
Where: 12° 08.1' S 96° 59.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
27 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 5.3 | < 0.02 | < 0.02 | 0.02 | 27.31 | 0.05 | < 0.02 | < 0.02 | 1.38 |
36 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 20.6 | < 0.02 | < 0.02 | 0.02 | 27.31 | 0.05 | < 0.02 | < 0.02 | 1.35 |
20 | 69.7 | < 0.02 | < 0.02 | 0.02 | 26.69 | 0.07 | < 0.02 | < 0.02 | 1.34 |
22 | 69.8 | < 0.02 | < 0.02 | < 0.02 | 26.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 69.9 | < 0.02 | < 0.02 | < 0.02 | 26.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 89.4 | < 0.02 | < 0.02 | < 0.02 | 26.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 89.4 | < 0.02 | < 0.02 | < 0.02 | 26.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 89.6 | 193.07 | 34.065 | 1.24 | 26.47 | 0.18 | 0.04 | 0.15 | 2.59 |
16 | 120.3 | 132.33 | 34.279 | 11.36 | 22.49 | 0.81 | < 0.02 | 0.05 | 12.62 |
14 | 201.2 | 118.71 | 34.533 | 19.65 | 15.63 | 1.40 | < 0.02 | 0.02 | 27.03 |
15 | 201.3 | < 0.02 | < 0.02 | < 0.02 | 15.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 300.7 | < 0.02 | < 0.02 | 27.04 | 11.53 | 1.90 | < 0.02 | < 0.02 | 39.21 |
12 | 400.4 | 112.05 | 34.700 | 28.11 | 9.84 | 1.96 | < 0.02 | < 0.02 | 38.51 |
11 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 500.7 | 107.90 | 34.683 | 30.83 | 8.69 | 2.14 | < 0.02 | < 0.02 | 42.80 |
8 | 750.7 | 81.55 | 34.653 | 36.04 | 6.77 | 2.59 | < 0.02 | < 0.02 | 76.01 |
6 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 5.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1000.4 | 92.72 | 34.623 | 36.83 | 5.32 | 2.67 | < 0.02 | < 0.02 | 97.72 |
1 | 1123 | 95.08 | 34.634 | 37.16 | 4.80 | 2.69 | < 0.02 | < 0.02 | 105.02 |
3 | 1123 | < 0.02 | < 0.02 | < 0.02 | 4.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1123.1 | < 0.02 | < 0.02 | < 0.02 | 4.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1123.2 | < 0.02 | < 0.02 | < 0.02 | 4.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |