Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-16 05:32 to 2022-10-16 06:12 UTC
Where: 12° 02.9' S 96° 50.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 30 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 27.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 27.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 4.1 | < 0.02 | < 0.02 | 0.02 | 27.29 | 0.05 | < 0.02 | < 0.02 | 1.42 |
| 22 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 27.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 27.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 27.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 20.5 | < 0.02 | < 0.02 | 0.02 | 27.21 | 0.05 | < 0.02 | < 0.02 | 1.42 |
| 18 | 65.1 | < 0.02 | < 0.02 | < 0.02 | 26.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 65.1 | < 0.02 | < 0.02 | 0.52 | 26.71 | 0.11 | < 0.02 | 0.07 | 1.81 |
| 19 | 65.3 | < 0.02 | < 0.02 | < 0.02 | 26.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 75.7 | < 0.02 | < 0.02 | 2.13 | 26.16 | 0.23 | < 0.02 | 0.20 | 3.24 |
| 13 | 83.8 | 184.27 | 34.073 | 2.53 | 26.11 | 0.25 | < 0.02 | 0.17 | 3.64 |
| 15 | 83.8 | < 0.02 | < 0.02 | < 0.02 | 26.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 83.9 | < 0.02 | < 0.02 | < 0.02 | 26.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 95.1 | 172.93 | 34.077 | 4.12 | 25.72 | 0.35 | < 0.02 | 0.14 | 4.94 |
| 10 | 200.8 | 113.17 | 34.611 | 19.81 | 15.90 | 1.41 | < 0.02 | 0.02 | 26.46 |
| 11 | 200.9 | < 0.02 | < 0.02 | < 0.02 | 15.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 300.6 | 99.42 | 34.672 | 27.19 | 11.00 | 1.91 | < 0.02 | < 0.02 | 39.25 |
| 8 | 400.6 | 124.60 | 34.722 | 27.18 | 9.61 | 1.88 | < 0.02 | < 0.02 | 33.09 |
| 6 | 500 | < 0.02 | < 0.02 | < 0.02 | 8.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 500 | 97.72 | 34.685 | 32.02 | 8.56 | 2.23 | < 0.02 | < 0.02 | 47.17 |
| 7 | 500.1 | < 0.02 | < 0.02 | < 0.02 | 8.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 687.6 | 78.20 | 34.668 | 35.61 | 7.11 | 2.55 | < 0.02 | < 0.02 | 71.19 |
| 2 | 687.7 | < 0.02 | < 0.02 | < 0.02 | 7.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 687.7 | < 0.02 | < 0.02 | < 0.02 | 7.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 687.8 | < 0.02 | < 0.02 | < 0.02 | 7.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |