Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-13 17:17 to 2022-10-13 18:18 UTC
Where: 11° 47.5' S 96° 49.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 21 | 4.5 | < 0.02 | < 0.02 | 0.03 | 27.37 | 0.05 | < 0.02 | < 0.02 | 1.46 |
| 22 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 27.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 20 | < 0.02 | < 0.02 | 0.03 | 27.38 | 0.05 | < 0.02 | < 0.02 | 1.50 |
| 19 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 26.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 50.5 | < 0.02 | < 0.02 | 0.03 | 26.93 | 0.07 | < 0.02 | < 0.02 | 1.41 |
| 17 | 80.2 | < 0.02 | < 0.02 | 0.25 | 26.74 | 0.12 | < 0.02 | 0.06 | 1.66 |
| 15 | 84.8 | 196.87 | 33.938 | 0.62 | 26.68 | 0.14 | < 0.02 | 0.12 | 2.04 |
| 16 | 84.9 | < 0.02 | < 0.02 | < 0.02 | 26.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 84.9 | < 0.02 | < 0.02 | < 0.02 | 26.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 100.6 | 139.57 | 34.095 | 8.99 | 24.48 | 0.66 | < 0.02 | 0.08 | 9.42 |
| 11 | 201.1 | < 0.02 | < 0.02 | < 0.02 | 15.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 201.1 | < 0.02 | < 0.02 | < 0.02 | 15.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 301.5 | 100.40 | 34.649 | 26.42 | 11.45 | 1.87 | < 0.02 | < 0.02 | 38.67 |
| 9 | 400.6 | 101.34 | 34.720 | 29.05 | 9.83 | 2.01 | < 0.02 | < 0.02 | 38.21 |
| 6 | 501.1 | < 0.02 | < 0.02 | < 0.02 | 8.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 501.1 | < 0.02 | < 0.02 | < 0.02 | 8.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 501.2 | 89.14 | 34.693 | 32.42 | 8.68 | 2.27 | < 0.02 | < 0.02 | 48.59 |
| 5 | 754.9 | 78.74 | 34.658 | 36.16 | 6.70 | 2.61 | < 0.02 | < 0.02 | 77.92 |
| 4 | 989.6 | 88.25 | 34.636 | 36.97 | 5.34 | 2.68 | < 0.02 | < 0.02 | 96.76 |
| 1 | 989.7 | 87.80 | 34.637 | 36.95 | 5.34 | 2.68 | < 0.02 | < 0.02 | 96.75 |
| 2 | 989.8 | < 0.02 | < 0.02 | < 0.02 | 5.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 989.8 | < 0.02 | < 0.02 | < 0.02 | 5.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |