Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-09 04:11 to 2022-10-09 06:02 UTC
Where: 10° 59.5' S 102° 21.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
32 | 11.1 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 11.5 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 11.6 | < 0.02 | < 0.02 | < 0.02 | 27.17 | 0.06 | < 0.02 | < 0.02 | 1.68 |
36 | 12.2 | < 0.02 | < 0.02 | < 0.02 | 27.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 12.5 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 12.9 | < 0.02 | < 0.02 | < 0.02 | 27.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 27.17 | 0.06 | < 0.02 | < 0.02 | 1.66 |
29 | 49.9 | < 0.02 | < 0.02 | 0.02 | 27.16 | 0.06 | < 0.02 | < 0.02 | 1.69 |
28 | 60.8 | < 0.02 | < 0.02 | 0.03 | 27.16 | 0.06 | < 0.02 | < 0.02 | 1.69 |
27 | 70.6 | < 0.02 | < 0.02 | < 0.02 | 26.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 70.7 | < 0.02 | < 0.02 | 0.35 | 26.83 | 0.10 | 0.04 | 0.05 | 1.83 |
26 | 70.8 | < 0.02 | < 0.02 | < 0.02 | 26.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 90.7 | < 0.02 | < 0.02 | 0.02 | 26.23 | 0.08 | 0.13 | < 0.02 | 1.24 |
23 | 100.8 | < 0.02 | < 0.02 | < 0.02 | 26.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 100.9 | < 0.02 | < 0.02 | 0.13 | 26.15 | 0.10 | 0.23 | 0.03 | 1.39 |
22 | 101 | < 0.02 | < 0.02 | < 0.02 | 26.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 122.5 | < 0.02 | < 0.02 | 9.06 | 24.12 | 0.69 | < 0.02 | 0.04 | 9.47 |
19 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 15.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 200.7 | 118.93 | 34.517 | 19.32 | 15.93 | 1.38 | < 0.02 | < 0.02 | 26.47 |
17 | 300.2 | < 0.02 | < 0.02 | < 0.02 | 11.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 300.4 | 97.81 | 34.606 | 27.10 | 11.42 | 1.91 | < 0.02 | < 0.02 | 40.16 |
15 | 400.1 | 92.72 | 34.692 | 29.86 | 10.03 | 2.07 | < 0.02 | < 0.02 | 41.79 |
14 | 500.8 | < 0.02 | < 0.02 | < 0.02 | 8.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 500.8 | 89.95 | 34.674 | 32.46 | 8.72 | 2.28 | < 0.02 | < 0.02 | 50.63 |
13 | 500.9 | < 0.02 | < 0.02 | 32.42 | 8.72 | 2.27 | < 0.02 | < 0.02 | 50.68 |
11 | 750.9 | < 0.02 | < 0.02 | 36.32 | 6.70 | 2.62 | < 0.02 | < 0.02 | 78.95 |
9 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 5.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 1000.7 | 88.61 | 34.647 | 37.14 | 5.35 | 2.70 | < 0.02 | < 0.02 | 98.63 |
10 | 1000.8 | < 0.02 | < 0.02 | < 0.02 | 5.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1500.9 | 115.27 | 34.710 | 37.12 | 3.58 | 2.69 | < 0.02 | < 0.02 | 115.00 |
5 | 2001.4 | 142.16 | 34.738 | 36.00 | 2.65 | 2.58 | < 0.02 | < 0.02 | 120.13 |
6 | 2001.5 | < 0.02 | < 0.02 | < 0.02 | 2.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2063.7 | < 0.02 | < 0.02 | < 0.02 | 2.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2063.8 | < 0.02 | < 0.02 | < 0.02 | 2.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2063.9 | 143.05 | 34.738 | 35.85 | 2.59 | 2.57 | < 0.02 | < 0.02 | 120.72 |
4 | 2064 | < 0.02 | < 0.02 | < 0.02 | 2.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |