Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-08 15:14 to 2022-10-08 16:23 UTC
Where: 11° 45.2' S 103° 16.6' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 4.3 | < 0.02 | < 0.02 | 0.06 | 26.36 | 0.08 | 0.04 | 0.02 | 1.17 |
27 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 20.2 | < 0.02 | < 0.02 | 0.06 | 26.37 | 0.08 | 0.04 | 0.02 | 1.19 |
22 | 50.1 | < 0.02 | < 0.02 | 0.04 | 26.37 | 0.08 | 0.05 | 0.02 | 1.13 |
23 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 26.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 76 | < 0.02 | < 0.02 | < 0.02 | 26.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 76 | < 0.02 | < 0.02 | 0.04 | 26.35 | 0.08 | 0.09 | 0.02 | 1.07 |
19 | 76.1 | < 0.02 | < 0.02 | < 0.02 | 26.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 100.6 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 100.6 | 197.22 | 34.065 | 1.09 | 26.23 | 0.16 | 0.06 | 0.08 | 2.03 |
15 | 200.7 | 118.62 | 34.497 | 17.62 | 17.54 | 1.26 | < 0.02 | 0.02 | 23.13 |
16 | 200.8 | < 0.02 | < 0.02 | < 0.02 | 17.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 301 | 106.03 | 34.588 | 25.37 | 12.00 | 1.80 | < 0.02 | < 0.02 | 38.07 |
12 | 400.2 | < 0.02 | < 0.02 | < 0.02 | 9.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 400.3 | 115.40 | 34.691 | 27.83 | 9.78 | 1.95 | 0.10 | < 0.02 | 38.14 |
9 | 500.7 | < 0.02 | < 0.02 | < 0.02 | 8.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 500.8 | 88.79 | 34.664 | 32.24 | 8.74 | 2.27 | < 0.02 | < 0.02 | 51.05 |
10 | 500.8 | < 0.02 | < 0.02 | < 0.02 | 8.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 751.4 | 79.99 | 34.650 | 36.05 | 6.79 | 2.60 | 0.07 | < 0.02 | 77.26 |
6 | 1000.7 | 91.38 | 34.620 | 36.83 | 5.34 | 2.68 | < 0.02 | < 0.02 | 98.49 |
5 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 5.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1000.9 | < 0.02 | < 0.02 | < 0.02 | 5.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1462.4 | 108.66 | 34.687 | 37.17 | 3.76 | 2.71 | < 0.02 | < 0.02 | 114.21 |
3 | 1462.4 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1462.6 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1462.6 | < 0.02 | < 0.02 | < 0.02 | 3.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |