Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-08 08:33 to 2022-10-08 09:53 UTC
Where: 11° 39.3' S 103° 38.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
32 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 27.05 | 0.06 | < 0.02 | < 0.02 | 1.79 |
27 | 8 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 21 | < 0.02 | < 0.02 | < 0.02 | 27.04 | 0.06 | < 0.02 | < 0.02 | 1.74 |
23 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 26.41 | 0.08 | 0.02 | < 0.02 | 1.11 |
20 | 78.4 | 204.19 | 34.058 | 0.03 | 26.32 | 0.11 | 0.33 | 0.02 | 1.49 |
22 | 78.6 | < 0.02 | < 0.02 | < 0.02 | 26.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 78.6 | < 0.02 | < 0.02 | < 0.02 | 26.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 89.9 | < 0.02 | < 0.02 | < 0.02 | 26.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 99.9 | 200.97 | 34.108 | 0.19 | 26.35 | 0.12 | 0.27 | 0.16 | 1.80 |
18 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 26.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 199.6 | < 0.02 | < 0.02 | < 0.02 | 16.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 199.7 | 117.77 | 34.501 | 18.59 | 16.60 | 1.33 | 0.03 | 0.02 | 24.97 |
14 | 300.6 | 105.44 | 34.601 | 25.48 | 11.87 | 1.81 | < 0.02 | < 0.02 | 38.06 |
13 | 400.6 | 96.96 | 34.631 | 29.45 | 9.91 | 2.07 | < 0.02 | < 0.02 | 45.36 |
12 | 450.4 | < 0.02 | < 0.02 | 28.20 | 9.52 | 1.97 | < 0.02 | < 0.02 | 38.94 |
10 | 500.9 | < 0.02 | < 0.02 | < 0.02 | 8.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 501 | 102.81 | 34.673 | 30.69 | 8.91 | 2.15 | < 0.02 | < 0.02 | 44.78 |
11 | 501.2 | < 0.02 | < 0.02 | < 0.02 | 8.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 750.9 | 81.64 | 34.643 | 36.00 | 6.72 | 2.60 | < 0.02 | < 0.02 | 78.66 |
5 | 1000.6 | 91.02 | 34.628 | 37.14 | 5.13 | 2.70 | < 0.02 | < 0.02 | 101.18 |
7 | 1001 | < 0.02 | < 0.02 | < 0.02 | 5.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1001 | < 0.02 | < 0.02 | < 0.02 | 5.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1410.5 | < 0.02 | < 0.02 | < 0.02 | 3.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1410.5 | 106.52 | 34.688 | 37.32 | 3.83 | 2.72 | < 0.02 | < 0.02 | 114.15 |
2 | 1410.7 | < 0.02 | < 0.02 | < 0.02 | 3.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1410.7 | < 0.02 | < 0.02 | < 0.02 | 3.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |