Deployment Details
Survey: - IN2022_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Fluorometer - CTD 22 - Wetlabs ECO,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-10-07 20:10 to 2022-10-07 23:51 UTC
Where: 11° 39.1' S 103° 58.6' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 27.16 | 0.06 | < 0.02 | < 0.02 | 1.83 |
36 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 27.16 | 0.06 | < 0.02 | < 0.02 | 1.86 |
33 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 27.16 | 0.06 | < 0.02 | < 0.02 | 1.80 |
32 | 66.3 | < 0.02 | < 0.02 | < 0.02 | 26.55 | 0.08 | 0.12 | < 0.02 | 1.03 |
31 | 80.4 | < 0.02 | < 0.02 | 0.02 | 26.43 | 0.09 | 0.07 | 0.02 | 0.95 |
29 | 89.7 | < 0.02 | < 0.02 | < 0.02 | 26.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 89.8 | < 0.02 | < 0.02 | < 0.02 | 26.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 89.9 | 205.93 | 34.008 | 0.09 | 26.39 | 0.10 | 0.20 | 0.04 | 1.20 |
27 | 100.8 | < 0.02 | < 0.02 | 0.23 | 26.32 | 0.12 | 0.37 | 0.06 | 1.63 |
26 | 120.9 | < 0.02 | < 0.02 | 1.12 | 25.82 | 0.16 | < 0.02 | 0.31 | 2.56 |
24 | 150.7 | < 0.02 | < 0.02 | 12.13 | 22.16 | 0.88 | < 0.02 | 0.03 | 13.34 |
25 | 151 | < 0.02 | < 0.02 | < 0.02 | 22.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 17.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 201.2 | < 0.02 | < 0.02 | 17.75 | 17.31 | 1.26 | < 0.02 | 0.02 | 22.85 |
21 | 301.1 | < 0.02 | < 0.02 | 25.46 | 11.87 | 1.81 | < 0.02 | < 0.02 | 37.91 |
20 | 451.4 | 119.38 | 34.683 | 28.43 | 9.33 | 1.98 | < 0.02 | < 0.02 | 38.21 |
17 | 501.4 | 101.11 | 34.669 | 31.59 | 8.56 | 2.21 | < 0.02 | < 0.02 | 46.67 |
18 | 501.4 | < 0.02 | < 0.02 | < 0.02 | 8.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 501.4 | < 0.02 | < 0.02 | < 0.02 | 8.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 751.4 | < 0.02 | < 0.02 | 36.23 | 6.62 | 2.62 | < 0.02 | < 0.02 | 79.63 |
13 | 1000.4 | 92.45 | 34.621 | 37.04 | 5.12 | 2.69 | < 0.02 | < 0.02 | 101.34 |
14 | 1000.4 | < 0.02 | < 0.02 | < 0.02 | 5.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1000.4 | < 0.02 | < 0.02 | < 0.02 | 5.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1500.1 | 113.17 | 34.706 | 37.21 | 3.54 | 2.70 | < 0.02 | < 0.02 | 115.94 |
10 | 2000.3 | 143.72 | 34.737 | 36.00 | 2.48 | 2.58 | < 0.02 | < 0.02 | 121.86 |
11 | 2000.4 | < 0.02 | < 0.02 | < 0.02 | 2.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2501.2 | 161.85 | 34.732 | 35.16 | 1.96 | 2.50 | < 0.02 | < 0.02 | 126.74 |
8 | 3000.5 | 174.13 | 34.724 | 34.77 | 1.60 | 2.45 | < 0.02 | < 0.02 | 130.97 |
7 | 3500.6 | 183.60 | 34.719 | 34.33 | 1.39 | 2.42 | < 0.02 | < 0.02 | 132.33 |
6 | 4000.9 | < 0.02 | < 0.02 | < 0.02 | 1.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 4500.7 | 198.96 | 34.713 | 33.60 | 1.17 | 2.36 | < 0.02 | < 0.02 | 131.19 |
3 | 4985.5 | < 0.02 | < 0.02 | < 0.02 | 1.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 4985.8 | < 0.02 | < 0.02 | < 0.02 | 1.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 4986.2 | < 0.02 | < 0.02 | < 0.02 | 1.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 4986.3 | 199.72 | 34.712 | 33.69 | 1.21 | 2.35 | < 0.02 | < 0.02 | 131.26 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Fluorometer - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |