Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-04-11 09:46 to 2023-04-11 10:11 UTC
Where: 43° 46.5' S 146° 01.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 26 | 7.8 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 8 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 8.7 | 248.76 | 35.352 | 1.54 | 15.20 | 0.21 | < 0.02 | 0.40 | 0.60 |
| 24 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 9 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 9 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 9.3 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 9.3 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 20 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 20.5 | 248.76 | 35.353 | 1.54 | 15.20 | 0.22 | < 0.02 | 0.39 | 0.64 |
| 13 | 40.2 | 248.14 | 35.352 | 1.56 | 15.20 | 0.22 | < 0.02 | 0.41 | 0.60 |
| 14 | 40.2 | < 0.02 | < 0.02 | < 0.02 | 15.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 15.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 60.5 | 247.38 | 35.350 | 1.64 | 15.17 | 0.23 | < 0.02 | 0.43 | 0.62 |
| 10 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 14.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 80.5 | 239.87 | 35.301 | 3.50 | 14.78 | 0.36 | < 0.02 | 0.30 | 1.03 |
| 7 | 100.3 | 227.15 | 35.221 | 7.50 | 13.56 | 0.62 | < 0.02 | 0.05 | 2.00 |
| 8 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 13.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 120.3 | < 0.02 | < 0.02 | < 0.02 | 12.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 120.4 | 228.89 | 35.168 | 9.02 | 12.74 | 0.72 | < 0.02 | 0.05 | 2.29 |
| 4 | 140.3 | < 0.02 | < 0.02 | < 0.02 | 12.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 140.4 | 231.84 | 35.107 | 10.15 | 12.20 | 0.79 | < 0.02 | 0.06 | 2.64 |
| 1 | 152.4 | 234.92 | 35.052 | 11.13 | 11.67 | 0.85 | < 0.02 | 0.06 | 2.99 |
| 2 | 152.6 | < 0.02 | < 0.02 | < 0.02 | 11.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |