Survey: - IN2023_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-04-11 00:51 to 2023-04-11 01:18 UTC
Where: 43° 42.0' S 145° 57.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
20 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 5.9 | 248.05 | 35.322 | 1.45 | 15.07 | 0.23 | 0.12 | 0.44 | 0.63 |
27 | 6 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 19.8 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 20.6 | 248.32 | 35.323 | 1.42 | 15.07 | 0.23 | 0.12 | 0.43 | 0.66 |
14 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 15.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 40.8 | 247.78 | 35.322 | 1.35 | 15.04 | 0.22 | 0.15 | 0.43 | 0.63 |
12 | 60.7 | 247.82 | 35.324 | 1.31 | 15.04 | 0.22 | 0.17 | 0.42 | 0.61 |
11 | 61 | < 0.02 | < 0.02 | < 0.02 | 15.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 80.5 | 234.78 | 35.287 | 3.97 | 14.56 | 0.40 | < 0.02 | 0.26 | 1.12 |
10 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 14.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 100 | 229.74 | 35.237 | 6.44 | 13.73 | 0.56 | < 0.02 | 0.09 | 1.66 |
8 | 100 | < 0.02 | < 0.02 | < 0.02 | 13.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 117.8 | 226.03 | 35.168 | 9.19 | 12.73 | 0.75 | < 0.02 | 0.15 | 2.32 |
5 | 118.2 | < 0.02 | < 0.02 | < 0.02 | 12.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 140.4 | 227.64 | 35.142 | 9.71 | 12.44 | 0.79 | < 0.02 | 0.16 | 2.49 |
4 | 140.4 | < 0.02 | < 0.02 | < 0.02 | 12.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 159.9 | < 0.02 | < 0.02 | < 0.02 | 11.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 160 | 234.51 | 35.063 | 10.88 | 11.72 | 0.85 | < 0.02 | 0.11 | 2.90 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |