Deployment Details
Survey: - IN2023_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-04-10 05:41 to 2023-04-10 06:21 UTC
Where: 43° 40.5' S 145° 55.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
34 | 9.1 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 9.4 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 9.7 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 9.7 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 10.8 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 10.8 | 256.53 | 35.318 | 0.68 | 14.82 | 0.19 | 0.13 | 0.21 | 0.60 |
32 | 10.9 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 11.1 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 11.2 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 11.2 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 11.5 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 12 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 12.4 | < 0.02 | < 0.02 | < 0.02 | 14.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 20.1 | 255.10 | 35.317 | 0.69 | 14.81 | 0.20 | 0.13 | 0.20 | 0.57 |
22 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 14.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 14.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 40.7 | 254.70 | 35.310 | 0.73 | 14.78 | 0.20 | 0.14 | 0.20 | 0.59 |
17 | 60 | < 0.02 | < 0.02 | < 0.02 | 14.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 60.1 | 257.69 | 35.309 | 0.77 | 14.73 | 0.20 | 0.15 | 0.21 | 0.57 |
16 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 80.5 | 250.32 | 35.306 | 0.80 | 14.71 | 0.21 | 0.17 | 0.20 | 0.60 |
13 | 100.6 | 247.96 | 35.284 | 2.05 | 14.53 | 0.29 | 0.12 | 0.19 | 0.83 |
14 | 100.8 | < 0.02 | < 0.02 | < 0.02 | 14.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 121.3 | 228.57 | 35.172 | 8.62 | 12.72 | 0.70 | < 0.02 | 0.06 | 2.09 |
11 | 121.3 | < 0.02 | < 0.02 | < 0.02 | 12.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 139.9 | < 0.02 | < 0.02 | < 0.02 | 12.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 140 | 231.25 | 35.137 | 9.43 | 12.36 | 0.76 | < 0.02 | 0.09 | 2.41 |
7 | 160 | 238.76 | 34.929 | 13.15 | 10.90 | 0.96 | < 0.02 | 0.03 | 3.73 |
8 | 160.1 | < 0.02 | < 0.02 | < 0.02 | 10.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 180.4 | 239.03 | 34.906 | 13.53 | 10.78 | 0.99 | < 0.02 | 0.03 | 3.84 |
6 | 180.5 | < 0.02 | < 0.02 | < 0.02 | 10.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 201.2 | 239.52 | 34.871 | 14.05 | 10.56 | 1.02 | < 0.02 | 0.04 | 4.03 |
4 | 201.3 | < 0.02 | < 0.02 | < 0.02 | 10.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 301.9 | 238.53 | 34.770 | 15.79 | 9.95 | 1.13 | < 0.02 | 0.03 | 4.81 |
2 | 302.2 | < 0.02 | < 0.02 | < 0.02 | 9.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |