Deployment Details
Survey: - IN2023_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-04-10 02:37 to 2023-04-10 03:04 UTC
Where: 43° 39.0' S 145° 57.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
27 | 9.2 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 9.3 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 9.5 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 9.6 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 9.6 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 9.7 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 9.9 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 10 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 10 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 10.2 | 250.32 | 35.336 | 0.76 | 15.09 | 0.19 | 0.21 | 0.31 | 0.53 |
29 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 10.9 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 11 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 11.3 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 11.4 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 11.5 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 11.5 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 19.1 | 250.10 | 35.338 | 0.76 | 15.10 | 0.18 | 0.23 | 0.31 | 0.50 |
16 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 40.1 | 249.92 | 35.336 | 0.77 | 15.09 | 0.20 | 0.25 | 0.32 | 0.54 |
14 | 40.2 | < 0.02 | < 0.02 | < 0.02 | 15.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 59.9 | < 0.02 | < 0.02 | < 0.02 | 14.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 60.3 | 252.92 | 35.316 | 0.72 | 14.86 | 0.20 | 0.20 | 0.27 | 0.51 |
10 | 81 | < 0.02 | < 0.02 | < 0.02 | 14.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 81 | 253.41 | 35.294 | 0.95 | 14.72 | 0.23 | 0.23 | 0.21 | 0.55 |
8 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 13.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 100 | 230.27 | 35.242 | 6.05 | 13.81 | 0.53 | < 0.02 | 0.09 | 1.59 |
5 | 119.3 | 229.69 | 35.190 | 8.22 | 12.80 | 0.69 | < 0.02 | 0.06 | 1.99 |
6 | 119.4 | < 0.02 | < 0.02 | < 0.02 | 12.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 140.7 | < 0.02 | < 0.02 | < 0.02 | 12.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 141.2 | 231.39 | 35.159 | 8.99 | 12.44 | 0.74 | < 0.02 | 0.09 | 2.20 |
1 | 152.7 | 234.29 | 35.081 | 10.35 | 11.80 | 0.81 | 0.04 | 0.09 | 2.68 |
2 | 152.7 | < 0.02 | < 0.02 | < 0.02 | 11.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |