Deployment Details
Survey: - IN2023_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 2235,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 4187,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-03-29 12:17 to 2023-03-29 12:45 UTC
Where: 43° 07.7' S 145° 19.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
29 | 20.3 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 16.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 16.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 20.6 | 245.32 | 35.384 | 0.26 | 16.36 | 0.13 | 0.02 | 0.10 | 0.24 |
25 | 20.6 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20.6 | < 0.02 | < 0.02 | < 0.02 | 16.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 16.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 16.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 16.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 20.9 | < 0.02 | < 0.02 | < 0.02 | 16.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 21 | < 0.02 | < 0.02 | < 0.02 | 16.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 39.7 | < 0.02 | < 0.02 | < 0.02 | 16.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 39.8 | < 0.02 | < 0.02 | < 0.02 | 16.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 39.8 | 245.23 | 35.374 | 0.32 | 16.23 | 0.14 | 0.06 | 0.12 | 0.26 |
13 | 60.8 | 231.75 | 35.308 | 3.04 | 15.37 | 0.33 | < 0.02 | 0.20 | 0.74 |
14 | 60.8 | < 0.02 | < 0.02 | < 0.02 | 15.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 60.9 | < 0.02 | < 0.02 | < 0.02 | 15.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 14.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 14.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 80.2 | 228.66 | 35.274 | 4.38 | 14.66 | 0.43 | < 0.02 | 0.11 | 1.00 |
7 | 100.5 | 228.26 | 35.239 | 6.01 | 13.79 | 0.54 | < 0.02 | 0.05 | 1.27 |
8 | 100.9 | < 0.02 | < 0.02 | < 0.02 | 13.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 101 | < 0.02 | < 0.02 | < 0.02 | 13.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 120.9 | 235.77 | 35.237 | 7.12 | 12.93 | 0.61 | < 0.02 | 0.04 | 1.53 |
5 | 121 | < 0.02 | < 0.02 | < 0.02 | 12.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 121.1 | < 0.02 | < 0.02 | < 0.02 | 12.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 142.1 | 236.35 | 35.236 | 7.20 | 12.85 | 0.62 | < 0.02 | 0.04 | 1.55 |
2 | 142.5 | < 0.02 | < 0.02 | < 0.02 | 12.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 142.7 | < 0.02 | < 0.02 | < 0.02 | 12.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
Conductivity CTD 24-SN 2235 | Seabird | SBE-4C | 2235 | |
Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 4187 | Seabird | SBE43 | 4187 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |