Deployment Details
Survey: - IN2022_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-09-11 13:18 to 2022-09-11 15:20 UTC
Where: 14° 33.6' S 145° 56.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
26 | 5.4 | 212.32 | 34.800 | < 0.02 | 26.22 | 0.06 | < 0.02 | < 0.02 | 1.07 |
32 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 5.8 | 217.37 | 34.800 | < 0.02 | 26.22 | 0.07 | < 0.02 | < 0.02 | 1.03 |
24 | 20 | 217.41 | 34.796 | 0.02 | 26.23 | 0.07 | < 0.02 | < 0.02 | 1.08 |
23 | 20 | 213.93 | 34.802 | 0.02 | 26.23 | 0.06 | < 0.02 | < 0.02 | 1.13 |
22 | 50.3 | 212.18 | 34.886 | < 0.02 | 25.59 | 0.06 | < 0.02 | < 0.02 | 1.03 |
21 | 50.4 | 215.22 | 34.886 | < 0.02 | 25.59 | 0.07 | < 0.02 | < 0.02 | 1.04 |
19 | 80.3 | 211.87 | 35.010 | < 0.02 | 24.77 | 0.08 | < 0.02 | < 0.02 | 0.89 |
20 | 80.3 | 213.12 | 35.011 | < 0.02 | 24.77 | 0.08 | < 0.02 | < 0.02 | 0.93 |
18 | 110.1 | 179.98 | 35.420 | 2.90 | 24.14 | 0.31 | < 0.02 | 0.06 | 1.09 |
17 | 110.2 | 174.76 | 35.421 | 2.91 | 24.08 | 0.31 | < 0.02 | 0.06 | 1.08 |
16 | 150.4 | 168.15 | 35.631 | 4.53 | 22.43 | 0.41 | < 0.02 | 0.02 | 1.24 |
15 | 150.4 | 170.02 | 35.638 | 4.68 | 22.43 | 0.42 | < 0.02 | 0.02 | 1.26 |
14 | 200.3 | 157.88 | 35.672 | 7.21 | 20.19 | 0.60 | < 0.02 | 0.02 | 1.88 |
13 | 249.9 | 161.85 | 35.548 | 8.55 | 18.40 | 0.70 | < 0.02 | < 0.02 | 2.60 |
12 | 300.7 | 166.99 | 35.341 | 10.60 | 16.33 | 0.83 | < 0.02 | < 0.02 | 3.74 |
11 | 400.8 | 171.63 | 34.955 | 16.37 | 12.65 | 1.20 | < 0.02 | < 0.02 | 7.37 |
10 | 475.7 | 185.52 | 34.697 | 20.68 | 9.96 | 1.47 | < 0.02 | < 0.02 | 10.64 |
9 | 599.8 | 201.69 | 34.492 | 25.05 | 7.44 | 1.73 | < 0.02 | < 0.02 | 16.64 |
8 | 625.6 | 196.51 | 34.462 | 26.69 | 6.90 | 1.85 | < 0.02 | < 0.02 | 20.60 |
7 | 800.3 | 185.03 | 34.435 | 30.90 | 5.24 | 2.14 | < 0.02 | < 0.02 | 39.98 |
6 | 999.8 | 172.21 | 34.469 | 33.10 | 4.43 | 2.31 | < 0.02 | < 0.02 | 57.59 |
5 | 1200.2 | 157.47 | 34.521 | 34.83 | 3.77 | 2.45 | < 0.02 | < 0.02 | 76.91 |
4 | 1400.7 | 147.83 | 34.560 | 35.92 | 3.33 | 2.54 | < 0.02 | < 0.02 | 91.56 |
3 | 1600.9 | 143.18 | 34.595 | 36.60 | 2.92 | 2.59 | < 0.02 | < 0.02 | 103.97 |
2 | 1800.8 | 143.32 | 34.619 | 36.75 | 2.61 | 2.60 | < 0.02 | < 0.02 | 111.55 |
1 | 2001.3 | 147.11 | 34.637 | 36.53 | 2.40 | 2.58 | < 0.02 | < 0.02 | 115.10 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |