Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: Autosal Salinometer,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-09-05 09:26 to 2022-09-05 11:12 UTC
Where: 15° 07.3' S 145° 57.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 25 | 4.5 | 209.64 | 34.901 | 0.02 | 25.57 | 0.05 | < 0.02 | < 0.02 | 0.87 |
| 32 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 5 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5 | < 0.02 | < 0.02 | < 0.02 | 25.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 25.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 25.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 25.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 10.4 | < 0.02 | < 0.02 | < 0.02 | 25.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 10.5 | 209.55 | 34.901 | 0.02 | 25.58 | 0.05 | < 0.02 | < 0.02 | 0.88 |
| 21 | 80.3 | 205.53 | 35.030 | 0.33 | 24.70 | 0.10 | < 0.02 | 0.13 | 0.79 |
| 22 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 24.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 130.4 | 142.78 | 35.671 | 6.74 | 23.74 | 0.59 | < 0.02 | 0.03 | 1.63 |
| 20 | 130.4 | < 0.02 | < 0.02 | < 0.02 | 23.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 350.7 | < 0.02 | < 0.02 | < 0.02 | 13.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 351 | 175.34 | 35.089 | 13.91 | 13.74 | 1.02 | < 0.02 | < 0.02 | 5.38 |
| 15 | 501.5 | 189.32 | 34.646 | 21.70 | 9.38 | 1.51 | < 0.02 | < 0.02 | 11.29 |
| 16 | 501.5 | < 0.02 | < 0.02 | < 0.02 | 9.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 581.3 | 204.01 | 34.520 | 24.02 | 7.87 | 1.65 | < 0.02 | < 0.02 | 13.65 |
| 14 | 581.3 | < 0.02 | < 0.02 | < 0.02 | 7.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 801 | 195.08 | 34.432 | 29.17 | 5.85 | 2.00 | < 0.02 | < 0.02 | 30.22 |
| 12 | 801 | < 0.02 | < 0.02 | < 0.02 | 5.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1001.1 | 172.12 | 34.466 | 33.19 | 4.47 | 2.29 | < 0.02 | < 0.02 | 56.21 |
| 10 | 1001.3 | < 0.02 | < 0.02 | < 0.02 | 4.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1500.8 | 145.06 | 34.574 | 36.44 | 3.14 | 2.55 | < 0.02 | 0.02 | 96.55 |
| 8 | 1500.9 | < 0.02 | < 0.02 | < 0.02 | 3.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1800.9 | < 0.02 | < 0.02 | < 0.02 | 2.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1801 | 145.28 | 34.622 | 36.71 | 2.56 | 2.58 | < 0.02 | < 0.02 | 110.95 |
| 3 | 2000.7 | 148.86 | 34.646 | 36.41 | 2.32 | 2.56 | < 0.02 | < 0.02 | 114.59 |
| 4 | 2000.8 | < 0.02 | < 0.02 | < 0.02 | 2.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 2313.4 | < 0.02 | < 0.02 | < 0.02 | 2.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2313.7 | 158.81 | 34.672 | 35.49 | 2.11 | 2.49 | < 0.02 | < 0.02 | 113.20 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |