Please login if you have access to particular applications.
Deployment Details
Survey: - IN2022_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CTD 22 - SN 1039,Conductivity CTD 22 - SN 4662,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 1794,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 4722,Transmissometer - CTD 22 -CST-1735DR
When: 2022-08-30 17:59 to 2022-08-30 18:07 UTC
Where: 13° 12.5' S 143° 53.7' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 20 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 4.4 | 208.83 | 34.892 | 0.06 | 25.53 | 0.07 | < 0.02 | < 0.02 | 0.88 |
| 32 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 9.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 9.5 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 9.6 | 208.83 | 34.892 | 0.05 | 25.53 | 0.07 | < 0.02 | < 0.02 | 0.90 |
| 3 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 20.2 | 209.28 | 34.891 | 0.06 | 25.53 | 0.07 | < 0.02 | < 0.02 | 0.89 |
| 2 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Conductivity CTD 22 - SN 4662 | Seabird | SBE4C | 4662 | |
| Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Seabird | SBE3P | 4722 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |