Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-12-16 19:30 to 2018-12-16 21:07 UTC
Where: 41° 12.9' S 148° 57.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2036 | 6 | < 0.02 | < 0.02 | < 0.02 | 16.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 6.4 | 258.41 | < 0.02 | < 0.02 | 16.56 | 0.13 | < 0.02 | < 0.02 | 0.22 |
2035 | 7.3 | < 0.02 | 35.368 | < 0.02 | 16.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 50.6 | 241.17 | 35.309 | 6.58 | 13.97 | 0.54 | 0.05 | 0.24 | 2.22 |
2123 | 80.3 | 224.47 | 35.296 | 9.71 | 13.29 | 0.72 | < 0.02 | 0.03 | 3.51 |
2030 | 100.5 | 225.31 | < 0.02 | 10.43 | 12.81 | 0.76 | < 0.02 | < 0.02 | 3.72 |
2031 | 100.6 | < 0.02 | 35.242 | < 0.02 | 12.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 200.3 | 235.77 | 35.106 | 11.35 | 11.83 | 0.82 | < 0.02 | < 0.02 | 3.79 |
2027 | 300.5 | 241.79 | < 0.02 | 15.21 | 10.08 | 1.06 | < 0.02 | < 0.02 | 4.52 |
2028 | 300.6 | < 0.02 | 34.789 | < 0.02 | 10.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 401.1 | < 0.02 | 34.703 | < 0.02 | 9.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 401.3 | 231.61 | < 0.02 | 18.03 | 9.42 | 1.24 | < 0.02 | < 0.02 | 6.23 |
2023 | 600.2 | 217.41 | < 0.02 | 23.18 | 7.85 | 1.57 | < 0.02 | < 0.02 | 11.72 |
2024 | 600.6 | < 0.02 | 34.521 | < 0.02 | 7.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 850.5 | 195.48 | < 0.02 | 29.09 | 5.87 | 1.97 | < 0.02 | < 0.02 | 28.93 |
2022 | 850.7 | < 0.02 | 34.437 | < 0.02 | 5.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 999.9 | < 0.02 | 34.427 | < 0.02 | 4.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 1000.1 | 187.35 | < 0.02 | 31.87 | 4.67 | 2.18 | < 0.02 | < 0.02 | 44.05 |
2020 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 4.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 1100.5 | 181.59 | < 0.02 | 32.87 | 4.21 | 2.26 | < 0.02 | < 0.02 | 52.77 |
2017 | 1100.6 | < 0.02 | 34.447 | < 0.02 | 4.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 1249.1 | 170.96 | < 0.02 | 34.32 | 3.57 | 2.37 | < 0.02 | < 0.02 | 67.69 |
2015 | 1249.1 | < 0.02 | 34.494 | < 0.02 | 3.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 1400.3 | 165.34 | < 0.02 | 34.97 | 3.13 | 2.42 | < 0.02 | < 0.02 | 78.09 |
2013 | 1400.5 | < 0.02 | 34.541 | < 0.02 | 3.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 1550.1 | 163.59 | < 0.02 | 35.03 | 2.81 | 2.43 | < 0.02 | < 0.02 | 85.53 |
2011 | 1550.2 | < 0.02 | 34.589 | < 0.02 | 2.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 1749.8 | 170.87 | < 0.02 | 34.25 | 2.46 | 2.37 | < 0.02 | < 0.02 | 89.10 |
2009 | 1750.2 | < 0.02 | 34.649 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2006 | 2000.9 | 176.05 | < 0.02 | 33.63 | 2.31 | 2.32 | < 0.02 | < 0.02 | 90.75 |
1201 | 2001.3 | < 0.02 | 34.679 | < 0.02 | 2.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 2061.8 | < 0.02 | 34.688 | < 0.02 | 2.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 2062 | 178.42 | < 0.02 | 33.44 | 2.25 | 2.30 | 0.02 | < 0.02 | 91.29 |
12001 | 2065.1 | 178.91 | < 0.02 | 33.45 | 2.24 | 2.30 | < 0.02 | < 0.02 | 91.43 |
12002 | 2065.2 | < 0.02 | 34.690 | < 0.02 | 2.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 2065.3 | < 0.02 | < 0.02 | < 0.02 | 2.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |