Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-12-13 18:54 to 2018-12-13 20:36 UTC
Where: 44° 23.2' S 147° 16.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 2033 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2123 | 5.1 | < 0.02 | 35.416 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2035 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 15.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2034 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2036 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 15.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2031 | 6.1 | 261.98 | < 0.02 | 0.45 | 15.20 | 0.16 | 0.05 | 0.08 | 0.91 |
| 2030 | 50.7 | 256.71 | 35.405 | 1.67 | 14.95 | 0.24 | 0.11 | 0.20 | 1.17 |
| 2029 | 80.5 | 245.32 | 35.362 | 7.01 | 13.45 | 0.57 | < 0.02 | 0.03 | 2.43 |
| 2028 | 101.1 | < 0.02 | 35.345 | < 0.02 | 13.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2027 | 101.2 | 246.53 | < 0.02 | 7.13 | 13.32 | 0.58 | < 0.02 | 0.02 | 2.41 |
| 2026 | 200.5 | 244.74 | 35.193 | 9.52 | 12.27 | 0.73 | < 0.02 | 0.02 | 3.02 |
| 2024 | 301.2 | 247.11 | < 0.02 | 11.82 | 11.16 | 0.87 | < 0.02 | < 0.02 | 3.54 |
| 2025 | 301.3 | < 0.02 | 35.009 | < 0.02 | 11.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2023 | 401.1 | 249.34 | 34.810 | 14.63 | 10.03 | 1.05 | < 0.02 | < 0.02 | 4.52 |
| 2021 | 599.9 | 216.20 | < 0.02 | 22.25 | 8.26 | 1.53 | < 0.02 | < 0.02 | 11.23 |
| 2022 | 600 | < 0.02 | 34.586 | < 0.02 | 8.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2020 | 850.7 | < 0.02 | 34.441 | < 0.02 | 5.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2019 | 850.8 | 195.75 | < 0.02 | 29.49 | 5.86 | 2.00 | < 0.02 | < 0.02 | 29.77 |
| 2018 | 988.4 | < 0.02 | 34.444 | < 0.02 | 4.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2017 | 991.8 | 187.22 | < 0.02 | 32.17 | 4.71 | 2.20 | < 0.02 | < 0.02 | 45.94 |
| 2015 | 1100.7 | 179.31 | < 0.02 | 33.73 | 4.05 | 2.32 | < 0.02 | < 0.02 | 57.21 |
| 2016 | 1100.7 | < 0.02 | 34.461 | < 0.02 | 4.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 1249.2 | < 0.02 | 34.488 | < 0.02 | 3.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2013 | 1249.7 | 176.23 | < 0.02 | 35.08 | 3.29 | 2.40 | < 0.02 | < 0.02 | 67.02 |
| 2011 | 1400.7 | 173.87 | < 0.02 | 35.24 | 2.96 | 2.42 | < 0.02 | < 0.02 | 73.72 |
| 2012 | 1400.9 | < 0.02 | 34.541 | < 0.02 | 2.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2009 | 1549.5 | 171.99 | < 0.02 | 34.98 | 2.73 | 2.41 | < 0.02 | < 0.02 | 80.75 |
| 2010 | 1549.7 | < 0.02 | 34.594 | < 0.02 | 2.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1201 | 1750.5 | 174.76 | < 0.02 | 34.49 | 2.49 | 2.38 | < 0.02 | < 0.02 | 85.94 |
| 2008 | 1750.6 | < 0.02 | 34.646 | < 0.02 | 2.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2006 | 2000.5 | < 0.02 | 34.691 | < 0.02 | 2.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2005 | 2000.8 | 178.55 | < 0.02 | 33.86 | 2.27 | 2.35 | < 0.02 | < 0.02 | 92.13 |
| 12003 | 2143.8 | 180.92 | < 0.02 | 33.62 | 2.15 | 2.33 | < 0.02 | < 0.02 | 95.88 |
| 12004 | 2144.1 | < 0.02 | 34.711 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12001 | 2148.8 | 180.74 | < 0.02 | 33.65 | 2.15 | 2.33 | < 0.02 | < 0.02 | 95.93 |
| 12002 | 2148.9 | < 0.02 | 34.711 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
| Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |