Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-12-07 03:08 to 2018-12-07 03:55 UTC
Where: 44° 13.9' S 146° 10.3' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2030 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 14.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 5 | < 0.02 | < 0.02 | < 0.02 | 14.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 5 | 277.43 | 35.298 | 0.62 | 14.55 | 0.18 | 0.03 | 0.06 | 0.42 |
2033 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 14.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 14.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 14.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 14.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 14.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 14.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 14.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 14.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 14.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 13.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 50.1 | 271.49 | 35.244 | 1.38 | 13.45 | 0.24 | 0.23 | 0.15 | 0.41 |
2022 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 13.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 13.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 79.9 | 254.08 | 35.206 | 7.04 | 12.56 | 0.57 | < 0.02 | 0.06 | 1.46 |
2020 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 12.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 100.5 | 255.06 | 35.199 | 7.64 | 12.37 | 0.60 | < 0.02 | 0.03 | 1.67 |
2018 | 100.6 | < 0.02 | < 0.02 | < 0.02 | 12.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 199.1 | 257.07 | 35.179 | 8.27 | 12.13 | 0.65 | < 0.02 | 0.02 | 1.99 |
2016 | 199.3 | < 0.02 | < 0.02 | < 0.02 | 12.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 301.4 | 244.97 | 35.018 | 11.83 | 11.18 | 0.87 | < 0.02 | 0.02 | 3.34 |
1214 | 301.6 | < 0.02 | < 0.02 | < 0.02 | 11.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 400.8 | 237.24 | 34.776 | 16.17 | 9.82 | 1.13 | < 0.02 | 0.02 | 4.97 |
2012 | 401.1 | < 0.02 | < 0.02 | < 0.02 | 9.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 500.2 | 234.74 | 34.648 | 18.81 | 8.98 | 1.30 | < 0.02 | < 0.02 | 6.44 |
2010 | 500.3 | < 0.02 | < 0.02 | < 0.02 | 8.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 601.1 | < 0.02 | < 0.02 | < 0.02 | 8.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2006 | 601.1 | < 0.02 | < 0.02 | < 0.02 | 8.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 601.2 | < 0.02 | < 0.02 | < 0.02 | 8.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 601.3 | 219.60 | 34.592 | 21.62 | 8.34 | 1.47 | < 0.02 | < 0.02 | 9.92 |
12001 | 700.3 | 206.65 | 34.499 | 25.15 | 7.34 | 1.70 | < 0.02 | < 0.02 | 15.30 |
12002 | 700.4 | < 0.02 | < 0.02 | < 0.02 | 7.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 700.4 | < 0.02 | < 0.02 | < 0.02 | 7.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 700.4 | < 0.02 | < 0.02 | < 0.02 | 7.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |