Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-12-02 21:55 to 2018-12-02 22:43 UTC
Where: 44° 11.3' S 146° 09.3' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2027 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 5 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 5 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 5.7 | 267.39 | 35.272 | 0.60 | 14.10 | 0.18 | 0.12 | 0.08 | 0.61 |
2033 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 49.7 | < 0.02 | < 0.02 | < 0.02 | 13.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 50.8 | 257.74 | 35.290 | 4.70 | 13.37 | 0.44 | 0.22 | 0.33 | 1.35 |
2015 | 79.5 | 255.68 | 35.237 | 5.55 | 12.86 | 0.50 | < 0.02 | 0.58 | 1.43 |
2016 | 79.7 | < 0.02 | < 0.02 | < 0.02 | 12.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 100 | < 0.02 | < 0.02 | < 0.02 | 12.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 100.4 | 254.43 | 35.219 | 6.25 | 12.64 | 0.53 | < 0.02 | 0.30 | 1.55 |
2011 | 199.6 | 252.38 | 35.175 | 9.06 | 12.10 | 0.70 | < 0.02 | < 0.02 | 2.55 |
2012 | 199.7 | < 0.02 | < 0.02 | < 0.02 | 12.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 301.3 | < 0.02 | < 0.02 | < 0.02 | 11.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 301.4 | 248.81 | 34.980 | 12.04 | 11.00 | 0.88 | < 0.02 | < 0.02 | 3.41 |
1201 | 398.1 | 232.73 | 34.747 | 17.18 | 9.63 | 1.19 | < 0.02 | < 0.02 | 5.65 |
2008 | 398.5 | < 0.02 | < 0.02 | < 0.02 | 9.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 500.6 | 228.08 | 34.665 | 19.31 | 8.98 | 1.33 | < 0.02 | < 0.02 | 7.56 |
2006 | 500.9 | < 0.02 | < 0.02 | < 0.02 | 9.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 600.7 | < 0.02 | < 0.02 | < 0.02 | 8.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 601 | 210.26 | 34.602 | 22.54 | 8.22 | 1.54 | < 0.02 | < 0.02 | 11.91 |
12002 | 723.3 | < 0.02 | < 0.02 | < 0.02 | 6.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 723.4 | 202.09 | 34.475 | 26.71 | 6.81 | 1.81 | < 0.02 | < 0.02 | 19.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |