Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-29 22:23 to 2018-11-29 23:27 UTC
Where: 44° 17.6' S 147° 23.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2034 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 13.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 13.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 13.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 13.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 4 | < 0.02 | < 0.02 | < 0.02 | 13.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 4 | 292.84 | 35.102 | 1.44 | 13.77 | 0.22 | 0.10 | 0.12 | 0.11 |
2030 | 49.8 | < 0.02 | < 0.02 | < 0.02 | 12.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 50.2 | 271.18 | 35.105 | 4.77 | 12.41 | 0.50 | 0.77 | 0.35 | 0.73 |
2027 | 80.7 | 264.84 | 35.124 | 6.86 | 12.16 | 0.61 | 0.36 | 0.46 | 1.48 |
2028 | 80.9 | < 0.02 | < 0.02 | < 0.02 | 12.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 100.8 | < 0.02 | < 0.02 | < 0.02 | 12.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 100.8 | 263.14 | 35.131 | 7.72 | 12.05 | 0.64 | 0.11 | 0.48 | 1.73 |
2024 | 201 | < 0.02 | < 0.02 | < 0.02 | 11.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 201 | 256.40 | 35.068 | 9.97 | 11.49 | 0.77 | < 0.02 | 0.03 | 2.65 |
2022 | 300.8 | < 0.02 | < 0.02 | < 0.02 | 10.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 300.8 | 246.84 | 34.957 | 12.62 | 10.88 | 0.92 | < 0.02 | 0.02 | 3.74 |
2020 | 401.1 | < 0.02 | < 0.02 | < 0.02 | 9.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 401.1 | 242.87 | 34.786 | 15.51 | 9.94 | 1.10 | < 0.02 | 0.02 | 4.79 |
2018 | 501 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 501.2 | 228.35 | 34.690 | 18.82 | 9.14 | 1.31 | < 0.02 | < 0.02 | 7.34 |
2016 | 601.1 | < 0.02 | < 0.02 | < 0.02 | 8.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 601.2 | 216.74 | 34.553 | 22.73 | 8.02 | 1.56 | < 0.02 | < 0.02 | 11.60 |
1214 | 700.5 | < 0.02 | < 0.02 | < 0.02 | 6.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 700.5 | 203.70 | 34.476 | 26.40 | 6.85 | 1.81 | < 0.02 | < 0.02 | 19.28 |
2011 | 800.2 | 194.81 | 34.442 | 29.30 | 5.82 | 2.02 | < 0.02 | < 0.02 | 30.32 |
2012 | 800.3 | < 0.02 | < 0.02 | < 0.02 | 5.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 900.8 | 192.58 | 34.421 | 31.15 | 4.96 | 2.16 | < 0.02 | < 0.02 | 39.25 |
2010 | 900.9 | < 0.02 | < 0.02 | < 0.02 | 4.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 1001 | < 0.02 | < 0.02 | < 0.02 | 4.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 1001.2 | 183.91 | 34.449 | 32.66 | 4.31 | 2.27 | < 0.02 | < 0.02 | 51.35 |
2005 | 1100.6 | 179.14 | 34.476 | 33.45 | 3.89 | 2.34 | < 0.02 | < 0.02 | 59.31 |
2006 | 1100.7 | < 0.02 | < 0.02 | < 0.02 | 3.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 1199.7 | < 0.02 | < 0.02 | < 0.02 | 3.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 1199.8 | 174.40 | 34.490 | 34.46 | 3.45 | 2.42 | < 0.02 | < 0.02 | 67.01 |
12001 | 1251.2 | 171.72 | 34.506 | 34.68 | 3.33 | 2.43 | < 0.02 | < 0.02 | 70.27 |
12002 | 1251.3 | < 0.02 | < 0.02 | < 0.02 | 3.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |