Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-29 18:35 to 2018-11-29 19:30 UTC
Where: 44° 17.4' S 147° 04.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2033 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 14.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 14.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 3.8 | 286.28 | 35.249 | 0.21 | 14.23 | 0.17 | 0.06 | 0.04 | 0.59 |
2024 | 49.6 | < 0.02 | < 0.02 | < 0.02 | 13.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 49.8 | 266.58 | 35.242 | 4.02 | 13.14 | 0.43 | 0.67 | 0.29 | 0.95 |
2021 | 80.7 | 260.91 | 35.209 | 6.23 | 12.66 | 0.53 | 0.07 | 0.47 | 1.38 |
2022 | 80.9 | < 0.02 | < 0.02 | < 0.02 | 12.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 100 | < 0.02 | < 0.02 | < 0.02 | 12.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 100 | 255.37 | 35.215 | 7.13 | 12.47 | 0.58 | < 0.02 | 0.08 | 1.72 |
2017 | 200.8 | 256.93 | 35.163 | 8.40 | 12.08 | 0.66 | < 0.02 | 0.05 | 2.14 |
2018 | 200.9 | < 0.02 | < 0.02 | < 0.02 | 12.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 299.5 | < 0.02 | < 0.02 | < 0.02 | 11.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 299.5 | 254.30 | 35.028 | 11.11 | 11.21 | 0.83 | < 0.02 | 0.02 | 3.16 |
1214 | 401.5 | < 0.02 | < 0.02 | < 0.02 | 10.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 401.6 | 239.52 | 34.819 | 15.27 | 10.09 | 1.09 | < 0.02 | < 0.02 | 4.90 |
2011 | 501.4 | 221.92 | 34.686 | 19.38 | 9.06 | 1.35 | 0.17 | < 0.02 | 8.09 |
2012 | 501.5 | < 0.02 | < 0.02 | < 0.02 | 9.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 600.3 | < 0.02 | < 0.02 | < 0.02 | 7.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 600.4 | 208.52 | 34.542 | 23.93 | 7.77 | 1.65 | < 0.02 | < 0.02 | 14.00 |
1201 | 700.9 | 200.30 | 34.472 | 27.00 | 6.72 | 1.85 | < 0.02 | < 0.02 | 21.38 |
2008 | 701 | < 0.02 | < 0.02 | < 0.02 | 6.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 801 | 193.56 | 34.444 | 29.50 | 5.70 | 2.03 | < 0.02 | < 0.02 | 32.04 |
2006 | 801 | < 0.02 | < 0.02 | < 0.02 | 5.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 900.3 | 185.43 | 34.436 | 31.52 | 4.85 | 2.19 | 0.03 | < 0.02 | 43.19 |
12004 | 900.3 | < 0.02 | < 0.02 | < 0.02 | 4.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 1015.4 | < 0.02 | < 0.02 | < 0.02 | 4.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 1015.4 | 183.11 | 34.446 | 32.59 | 4.37 | 2.27 | 0.06 | < 0.02 | 50.86 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |