Deployment Details
Survey: - IN2018_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 2312,Licor - CTD 24 - SN 70677,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1735DR
When: 2018-11-27 21:19 to 2018-11-27 22:08 UTC
Where: 44° 15.9' S 147° 14.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2031 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2123 | 3 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 3 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 3.1 | 275.60 | 35.217 | 1.75 | 13.57 | 0.26 | 0.20 | 0.15 | 0.53 |
2025 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 50.3 | 258.32 | 35.209 | 5.88 | 12.70 | 0.51 | < 0.02 | 0.28 | 1.42 |
2022 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 12.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 101.6 | 258.50 | 35.184 | 7.73 | 12.25 | 0.62 | < 0.02 | 0.10 | 1.96 |
2020 | 101.6 | < 0.02 | < 0.02 | < 0.02 | 12.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 201.6 | 241.39 | 35.070 | 11.11 | 11.60 | 0.83 | < 0.02 | 0.03 | 3.49 |
2018 | 201.7 | < 0.02 | < 0.02 | < 0.02 | 11.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 280.8 | 233.35 | 34.934 | 14.08 | 10.75 | 1.01 | < 0.02 | < 0.02 | 4.66 |
2016 | 280.9 | < 0.02 | < 0.02 | < 0.02 | 10.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 301.2 | < 0.02 | < 0.02 | < 0.02 | 10.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 301.2 | 258.32 | 34.869 | 12.81 | 10.39 | 0.94 | < 0.02 | < 0.02 | 3.59 |
2011 | 401.7 | 235.77 | 34.748 | 16.84 | 9.64 | 1.19 | < 0.02 | < 0.02 | 5.78 |
2012 | 401.7 | < 0.02 | < 0.02 | < 0.02 | 9.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 496.3 | 227.55 | 34.654 | 19.52 | 8.91 | 1.37 | < 0.02 | < 0.02 | 8.00 |
2010 | 496.6 | < 0.02 | < 0.02 | < 0.02 | 8.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 602.4 | < 0.02 | < 0.02 | < 0.02 | 8.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 602.5 | 211.92 | 34.564 | 23.03 | 8.00 | 1.59 | < 0.02 | < 0.02 | 12.60 |
2005 | 703.1 | 202.94 | 34.474 | 26.34 | 6.95 | 1.81 | < 0.02 | < 0.02 | 18.66 |
2006 | 703.2 | < 0.02 | < 0.02 | < 0.02 | 6.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 800.9 | < 0.02 | < 0.02 | < 0.02 | 6.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 801 | 199.19 | 34.442 | 28.33 | 6.15 | 1.95 | < 0.02 | < 0.02 | 25.45 |
12001 | 882.5 | 194.41 | 34.444 | 29.58 | 5.62 | 2.05 | < 0.02 | < 0.02 | 32.93 |
12002 | 882.6 | < 0.02 | < 0.02 | < 0.02 | 5.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 2312 | Seabird | SBE4C | 2312 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |