Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 25
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-16 16:22 to 2021-07-16 18:53 UTC
Where: 11° 30.1' S 104° 25.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
30 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 4.7 | 201.73 | 33.864 | < 0.02 | 28.28 | < 0.02 | < 0.02 | < 0.02 | 1.86 |
32 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 50.5 | 201.91 | 33.887 | < 0.02 | 28.26 | < 0.02 | < 0.02 | < 0.02 | 1.87 |
27 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 28.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 100.9 | < 0.02 | < 0.02 | < 0.02 | 23.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 100.9 | < 0.02 | < 0.02 | 8.63 | 23.99 | 0.65 | < 0.02 | 0.07 | 9.69 |
25 | 101 | < 0.02 | < 0.02 | < 0.02 | 23.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 14.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 200.7 | 117.15 | 34.537 | 20.78 | 14.93 | 1.44 | < 0.02 | < 0.02 | 28.94 |
20 | 301 | 97.72 | 34.650 | 26.78 | 11.66 | 1.84 | < 0.02 | < 0.02 | 38.13 |
19 | 401.5 | 102.94 | 34.705 | 29.28 | 9.83 | 1.99 | < 0.02 | < 0.02 | 39.70 |
17 | 500.4 | < 0.02 | < 0.02 | < 0.02 | 8.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 500.4 | < 0.02 | < 0.02 | < 0.02 | 8.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 500.4 | 86.87 | 34.690 | 33.37 | 8.53 | 2.30 | < 0.02 | < 0.02 | 51.47 |
15 | 600.7 | < 0.02 | < 0.02 | 35.26 | 7.79 | 2.47 | < 0.02 | < 0.02 | 62.22 |
14 | 700.3 | 82.13 | 34.647 | 36.04 | 6.93 | 2.55 | < 0.02 | < 0.02 | 75.30 |
13 | 800.8 | < 0.02 | < 0.02 | 36.75 | 6.07 | 2.61 | < 0.02 | < 0.02 | 86.64 |
10 | 999.9 | 95.71 | 34.617 | 37.23 | 5.06 | 2.66 | < 0.02 | < 0.02 | 101.75 |
11 | 1000 | < 0.02 | < 0.02 | < 0.02 | 5.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 1500.6 | 111.56 | 34.700 | 37.55 | 3.70 | 2.69 | < 0.02 | < 0.02 | 115.09 |
8 | 2000.4 | < 0.02 | < 0.02 | < 0.02 | 2.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2000.5 | 142.87 | 34.734 | 36.29 | 2.56 | 2.56 | 0.04 | < 0.02 | 120.96 |
6 | 2500.2 | 160.56 | 34.732 | 35.50 | 2.05 | 2.48 | 0.02 | < 0.02 | 125.52 |
4 | 2999.9 | 171.45 | 34.726 | 35.10 | 1.72 | 2.44 | < 0.02 | < 0.02 | 129.35 |
5 | 3000.4 | < 0.02 | < 0.02 | < 0.02 | 1.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3428.2 | < 0.02 | < 0.02 | < 0.02 | 1.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3428.2 | < 0.02 | < 0.02 | < 0.02 | 1.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3428.6 | 182.62 | 34.720 | 34.69 | 1.45 | 2.39 | 0.02 | < 0.02 | 131.83 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |