Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-16 04:05 to 2021-07-16 05:16 UTC
Where: 11° 22.4' S 104° 30.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
25 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 3.7 | 202.54 | 33.827 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | 1.77 |
29 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 28.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 25.3 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | 1.75 |
17 | 51.1 | 202.45 | 33.874 | < 0.02 | 28.30 | < 0.02 | < 0.02 | < 0.02 | 1.75 |
18 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 28.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 85.8 | < 0.02 | < 0.02 | < 0.02 | 26.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 85.9 | < 0.02 | < 0.02 | < 0.02 | 26.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 85.9 | 169.67 | 34.393 | 2.34 | 26.35 | 0.34 | < 0.02 | 0.21 | 4.89 |
13 | 201.3 | < 0.02 | < 0.02 | < 0.02 | 15.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 201.4 | 119.29 | 34.526 | 20.30 | 15.09 | 1.43 | < 0.02 | < 0.02 | 28.03 |
11 | 350.8 | 96.83 | 34.697 | 29.12 | 10.30 | 2.00 | < 0.02 | < 0.02 | 39.75 |
8 | 500.7 | 88.88 | 34.694 | 32.71 | 8.81 | 2.25 | < 0.02 | < 0.02 | 48.23 |
9 | 500.8 | < 0.02 | < 0.02 | < 0.02 | 8.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 500.8 | < 0.02 | < 0.02 | < 0.02 | 8.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 750.9 | 83.96 | 34.644 | 36.19 | 6.83 | 2.56 | < 0.02 | < 0.02 | 75.83 |
6 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1000.2 | < 0.02 | < 0.02 | < 0.02 | 5.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1000.2 | 94.10 | 34.616 | 37.31 | 5.13 | 2.67 | 0.02 | < 0.02 | 100.72 |
1 | 1322.3 | 102.85 | 34.654 | 37.71 | 4.18 | 2.70 | < 0.02 | < 0.02 | 111.79 |
3 | 1322.3 | < 0.02 | < 0.02 | < 0.02 | 4.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1322.3 | < 0.02 | < 0.02 | < 0.02 | 4.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |