Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-15 17:57 to 2021-07-15 19:05 UTC
Where: 11° 24.3' S 104° 25.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
34 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 4.9 | 201.69 | 33.819 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | 1.91 |
36 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 28.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 49.6 | 201.60 | 33.967 | < 0.02 | 28.39 | 0.03 | < 0.02 | < 0.02 | 1.96 |
18 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 28.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 70.6 | < 0.02 | < 0.02 | < 0.02 | 27.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 70.7 | 187.62 | 34.394 | 0.37 | 27.41 | 0.18 | 0.02 | 0.12 | 3.04 |
16 | 70.7 | < 0.02 | < 0.02 | < 0.02 | 27.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 15.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 200.3 | 118.04 | 34.529 | 20.17 | 15.36 | 1.42 | < 0.02 | < 0.02 | 27.82 |
11 | 350.4 | 96.42 | 34.696 | 28.91 | 10.38 | 1.99 | < 0.02 | < 0.02 | 39.86 |
8 | 500.5 | 86.33 | 34.689 | 33.26 | 8.60 | 2.29 | < 0.02 | < 0.02 | 50.95 |
9 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 750.5 | 86.24 | 34.630 | 36.68 | 6.19 | 2.60 | < 0.02 | < 0.02 | 85.61 |
6 | 999 | < 0.02 | < 0.02 | < 0.02 | 4.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 999 | < 0.02 | < 0.02 | < 0.02 | 4.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 999 | 95.22 | 34.618 | 37.39 | 4.94 | 2.67 | < 0.02 | < 0.02 | 103.68 |
2 | 1248 | < 0.02 | < 0.02 | < 0.02 | 4.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1248.1 | 101.87 | 34.647 | 37.68 | 4.28 | 2.69 | < 0.02 | < 0.02 | 111.07 |
3 | 1248.1 | < 0.02 | < 0.02 | < 0.02 | 4.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |