Please login if you have access to particular applications.
Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-14 22:43 to 2021-07-15 00:17 UTC
Where: 10° 51.4' S 104° 43.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
27 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 4.6 | 200.57 | 33.818 | 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | 1.83 |
21 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 28.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 49.2 | 200.35 | 33.839 | 0.02 | 28.69 | < 0.02 | < 0.02 | < 0.02 | 1.85 |
19 | 49.3 | < 0.02 | < 0.02 | < 0.02 | 28.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 74.5 | 188.87 | 34.226 | 0.13 | 27.85 | 0.14 | < 0.02 | 0.06 | 2.87 |
17 | 74.6 | < 0.02 | < 0.02 | < 0.02 | 27.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 74.6 | < 0.02 | < 0.02 | < 0.02 | 27.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 200.9 | 114.42 | 34.531 | 22.20 | 14.07 | 1.56 | < 0.02 | < 0.02 | 32.01 |
14 | 201 | < 0.02 | < 0.02 | < 0.02 | 14.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 350.5 | 92.49 | 34.624 | 30.20 | 10.02 | 2.09 | < 0.02 | < 0.02 | 46.45 |
9 | 501.5 | 78.29 | 34.730 | 33.75 | 8.85 | 2.32 | < 0.02 | < 0.02 | 49.96 |
11 | 501.6 | < 0.02 | < 0.02 | < 0.02 | 8.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 501.6 | < 0.02 | < 0.02 | < 0.02 | 8.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 750.4 | 81.28 | 34.652 | 36.50 | 6.61 | 2.58 | < 0.02 | < 0.02 | 80.12 |
5 | 1000 | 92.94 | 34.625 | 37.22 | 5.21 | 2.66 | < 0.02 | < 0.02 | 100.78 |
6 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1000.2 | < 0.02 | < 0.02 | < 0.02 | 5.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1499.4 | 113.80 | 34.709 | 37.42 | 3.57 | 2.68 | < 0.02 | < 0.02 | 115.69 |
2 | 1972.8 | < 0.02 | < 0.02 | < 0.02 | 2.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1972.9 | < 0.02 | < 0.02 | < 0.02 | 2.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1972.9 | 145.46 | 34.737 | 36.16 | 2.44 | 2.54 | < 0.02 | < 0.02 | 122.55 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |