Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-14 01:18 to 2021-07-14 02:34 UTC
Where: 11° 22.5' S 104° 57.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
28 | 2.3 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 2.8 | 201.24 | 33.917 | 0.02 | 28.42 | 0.03 | < 0.02 | < 0.02 | 1.92 |
36 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 49.8 | 200.93 | 33.918 | 0.02 | 28.43 | 0.03 | < 0.02 | < 0.02 | 1.96 |
19 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 70.6 | 182.75 | 34.289 | 0.50 | 27.26 | 0.21 | 0.03 | 0.08 | 3.71 |
17 | 70.7 | < 0.02 | < 0.02 | < 0.02 | 27.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 70.7 | < 0.02 | < 0.02 | < 0.02 | 27.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 201.4 | 116.43 | 34.528 | 20.43 | 15.18 | 1.44 | < 0.02 | < 0.02 | 28.65 |
14 | 201.5 | < 0.02 | < 0.02 | < 0.02 | 15.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 351.3 | 90.80 | 34.675 | 29.13 | 10.55 | 2.01 | < 0.02 | < 0.02 | 41.38 |
9 | 500.9 | 84.41 | 34.699 | 32.91 | 8.81 | 2.26 | < 0.02 | < 0.02 | 49.03 |
11 | 500.9 | < 0.02 | < 0.02 | < 0.02 | 8.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 501.1 | < 0.02 | < 0.02 | < 0.02 | 8.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 751.2 | 80.93 | 34.648 | 36.49 | 6.63 | 2.59 | < 0.02 | < 0.02 | 80.00 |
6 | 999.8 | < 0.02 | < 0.02 | < 0.02 | 5.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 999.8 | 91.11 | 34.628 | 37.31 | 5.20 | 2.66 | < 0.02 | < 0.02 | 101.12 |
7 | 1000 | < 0.02 | < 0.02 | < 0.02 | 5.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1250 | 100.40 | 34.647 | 37.65 | 4.28 | 2.70 | < 0.02 | < 0.02 | 112.27 |
2 | 1356.2 | < 0.02 | < 0.02 | < 0.02 | 4.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1356.2 | 102.36 | 34.665 | 37.63 | 4.13 | 2.70 | < 0.02 | < 0.02 | 112.85 |
3 | 1356.3 | < 0.02 | < 0.02 | < 0.02 | 4.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |