Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 16
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-13 09:30 to 2021-07-13 10:43 UTC
Where: 11° 24.1' S 104° 57.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
26 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 28.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 28.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 5.7 | 202.89 | 33.865 | 0.02 | 28.39 | 0.02 | < 0.02 | < 0.02 | 1.99 |
22 | 50 | < 0.02 | < 0.02 | < 0.02 | 28.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 50.9 | < 0.02 | < 0.02 | 0.02 | 28.29 | 0.03 | < 0.02 | < 0.02 | 1.94 |
19 | 76.1 | < 0.02 | < 0.02 | < 0.02 | 25.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 76.3 | 155.64 | 34.373 | 4.88 | 25.42 | 0.48 | < 0.02 | 0.16 | 6.88 |
20 | 76.4 | < 0.02 | < 0.02 | < 0.02 | 25.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 201.4 | 114.96 | 34.528 | 20.90 | 14.81 | 1.48 | < 0.02 | < 0.02 | 29.45 |
17 | 202.1 | < 0.02 | < 0.02 | < 0.02 | 14.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 300.8 | 94.10 | 34.636 | 27.15 | 11.68 | 1.89 | < 0.02 | < 0.02 | 38.72 |
14 | 400.6 | < 0.02 | < 0.02 | 29.75 | 10.15 | 2.04 | < 0.02 | < 0.02 | 41.19 |
12 | 501.1 | < 0.02 | < 0.02 | < 0.02 | 9.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 501.2 | 84.72 | 34.714 | 32.51 | 9.05 | 2.23 | < 0.02 | < 0.02 | 46.30 |
13 | 501.2 | < 0.02 | < 0.02 | < 0.02 | 9.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 600.7 | < 0.02 | < 0.02 | 34.85 | 8.00 | 2.44 | < 0.02 | < 0.02 | 60.26 |
9 | 700.8 | 80.21 | 34.652 | 36.16 | 6.93 | 2.56 | < 0.02 | < 0.02 | 75.50 |
8 | 799.8 | 84.19 | 34.633 | 36.62 | 6.26 | 2.61 | < 0.02 | < 0.02 | 85.34 |
6 | 1000.2 | < 0.02 | < 0.02 | < 0.02 | 5.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1000.2 | 91.29 | 34.621 | 37.21 | 5.27 | 2.66 | < 0.02 | < 0.02 | 99.86 |
7 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 5.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1199.8 | 100.13 | 34.641 | 37.63 | 4.35 | 2.70 | < 0.02 | < 0.02 | 111.84 |
3 | 1325.3 | < 0.02 | < 0.02 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1325.5 | 102.27 | 34.672 | 37.71 | 4.08 | 2.70 | < 0.02 | < 0.02 | 113.60 |
2 | 1325.7 | < 0.02 | < 0.02 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |